4. Type "setup" and press Enter to enter the Authentication menu.
5. Enter the user name and password of the PDU device at the Authentication menu.
Note: The default username is "cyber" and the default password is "cyber". For
further information and configuration via Hyper Terminal, see Appendix A- Hyper
Terminal.

Operation

Metered Readout

The Metered Readout provides instant status updates of the
B1
B2
YU0-0000028-00
- Normal
Tx/Rx
- Warning
- Overload
PDU's Voltage, Current, Power conditions as well as the local
Amps
Link
Volts
Select
Serial
Port
IP address of the unit to the user. In addition, it also allows
KW
Reset
the user to control each outlet of the PDU.

Basic Operation

Screen Selection- To toggle the different status screens, press the Select button
next to the PDU status screen.
Pressing the Select once will toggle to the next status screen.
Pressing and holding the Select button for 3 seconds will display the
local IP address of the unit.
Pressing and holding the Select button for 6 seconds will enter the outlet
control mode.

PDU Status Screen

Current Level

The Current Level screen shows the total current draw of the
Amps
Volts
connected equipment. Units are listed in Amps.
KW

Input Voltage

The Input Voltage screen measures the AC voltage that the
Amps
system is receiving from the utility wall receptacle. This can
Volts
be used as a diagnostic tool to identify poor-quality input
KW
power. Units are listed in Volts.

Power

The Power screen shows the total power that the devices
Amps
connected to the PDU consumes. Units are listed in kilowatts.
Volts
KW

IP Address

The IP Address screen displays the local IP address of the
Amps
Volts
PDU unit. Note: If the PDU is not connected to a LAN, the
KW
readout will display the default IP address.
Outlet Control (switched series only)
The Outlet screen shows the condition of each outlet in
Amps
sequence. When the outlet is on, the light below this outlet is
Volts
KW
on and an upper square appears next to the number of the
outlet. To switch the outlet to off mode, press the Select
Amps
button once and the upper square will change into lower
Volts
KW
square. At this time, please wait for 1 second and the outlet
will turn to off mode automatically.

Remote Management

The remote management function of the CyberPower PDU provides for
monitoring the PDU vitals, controlling outlets, and utilizing SNMP functionality.
Remote management is performed via the web interface. To access the web
interface, please follow the instructions below:
1. Enter the IP address of the PDU into a web browser (Internet Explorer, Firefox).
2. Enter the user name and password of the PDU device at the authentication screen.
Note: The default username is "cyber" and the default password is "cyber".
After entering Web interface for the first time, please set the correct time in
[System=>General=>Date & Time]
For additional information about the features and functionality of CyberPower
Management Console, please refer to the PDU Software Installation CD.
11
Operation

LED Indicators

n I
d
c i
t a
r o
S
a t
u t
Green
Load
Orange
Red
O
f f
On(Green)
Tx/Rx
Flash
O
n
LINK
Off
O
n
Outlet
O
f f

Device Reset

To reset all the settings to default except for the IP address, press and
hold the Reset Button for 3 seconds.
To reset all the settings to default, press and hold the Reset Button for 6
seconds.

Unattended/Automatic Shutdown

PowerPanel Business Edition software automatically saves open files and
gracefully shuts down the operating system in an intelligent and orderly fashion.
PowerPanel must be installed on every PC for which the shut down is to take place.
The PC receives SNMP messages directly from the PDU, and these messages can
be scheduled for an exact date/time, or can be performed immediately. Follow the
directions below for setting up Unattended/Automatic Shutdown.
Step 1. PC Configuration
1. Install PowerPanel Business Edition Client on every PC that will be part of the shut
down process. (Follow the instructions in the PowerPanel Business Edition Client
user manual).
2. Configure the settings in PowerPanel Business Edition Client. See the PowerPanel
Business Edition Client User Manual for additional help.
Step 2. PDU Configuration
1. Verify that the IP address of all PCs that will be part of the shut down process are
included in the Client List of web interface (For additional information, please refer
to the user's manual in the PDU Software Installation CD).
Step 3. Notification
Notifying the PCs of potential outlet shutdown can be accomplished using the
following methods:
Outlets Control Menu: Performing the task of turning off or rebooting outlets.
Scheduling Menu: Setting the scheduler to perform the task of turning off or
rebooting outlets. The notification will occur prior to the scheduled date/time.
Outlet Overload: In event of a PDU overload, notification will be sent prior to the
PDU shutting down.

Firmware Upgrade

By upgrading the Firmware, you can obtain new features and
updates/improvements to existing functionality. There are two files to update in order
to upgrade the firmware version:
* cpspduafw_XXX.bin
* cpspduadata_XXX.bin
Use the following steps to upgrade the firmware.
1. Download the latest firmware from cyberpowersystems.com
2. Extract the file to "C:\"
3. Open a command prompt window
4. Login to the PDU with FTP command, type
* ftp
* ftp> open
* To [current ip of the PDU] [port] ; EX: To 192.168.22.126 21
* Input USER NAME and PASSWORD (same as the administrator account in Web
interface default : cyber ; cyber)
s
Description
The total PDU power load is normal.
Near overload.
Overload.
T
h
e
P
D
U
p
o
w
r e
s i
o
. f f
The PDU power is on.
Receiving/transmitting data packet.
Reset finished.
n I
d
c i
a
e t
s
h t
e
P
D
U
s i
c
o
n
n
Indicates the PDU is not connected to the
LAN.
T
h
e
o
u
l t
t e
s i
o
n
a
n
d
p
o r
v
d i
T
h
e
o
u
l t
t e
s i
o
. f f
e
c
e t
d
o t
h t
e
L
A
. N
n i
g
p
o
w
e
. r
12

Advertisement

Table of Contents
loading

Table of Contents