CyberPower PDU15SW8FNET User Manual

CyberPower PDU15SW8FNET User Manual

Cyberpower power distribution unit user manual
Hide thumbs Also See for PDU15SW8FNET:

Advertisement

User Manual
Power
Distribution
Unit

Advertisement

Table of Contents
loading

Summary of Contents for CyberPower PDU15SW8FNET

  • Page 1 User Manual Power Distribution Unit...
  • Page 2: Table Of Contents

    Troubleshooting ..........20 Frequently Ask Questions (FAQ) ......20 Conformance Approvals ........20 Customer Service & Warranty ......21 Product Registration ..........21 CyberPower International ........21 Limited Warranty ............. 21 Appendix A-Hyper Terminal ........22 Appendix B-Power Device Network Utility...23 Overview ..............23 Installation ..............23 Launch Program ............
  • Page 3: Model List

    . Q ua lity . Va lu U s e r' s M a n u a l Cable Ties / Qty. 10 User Manual / Registration Card / CD Documentation For more information on CyberPower products, visit www.CPSww.com...
  • Page 4: For 0U Series

    . Va lu U s e r' s M a n u a l Cable Ties: Qty. 20 (16 Outlets) User Manual / Registration Card / CD Qty. 30 (24 Outlets) Documentation For more information on CyberPower products, visit www.CPSww.com...
  • Page 5: For 2U Series

    User Manual / Registration Card / CD Documentation Before using, please check to ensure the package contains all the items shown above. If there are missing parts, please contact your local CyberPower (refer to CyberPower International P.21) Check for technical support. Safety Precautions...
  • Page 6: Proruct Features

    UL 60950-1 UL 60950-1 Certifications CSA C22.2 CSA C22.2 CSA C22.2 CSA C22.2 FCC Class A CE, FCC Class A FCC Class A CE, FCC Class A Warranty Product Warranty 2 years For more information on CyberPower products, visit www.CPSww.com...
  • Page 7: 20A Series

    UL 60950-1 UL 60950-1 Certifications CSA C22.2 CSA C22.2 CSA C22.2 CSA C22.2 FCC Class A CE, FCC Class A FCC Class A CE, FCC Class A Warranty Product Warranty 2 years For more information on CyberPower products, visit www.CPSww.com...
  • Page 8: 15A Series

    0 to 95% Non-condensing Altitude 14700 ft/4500 m Temperature F to 104 F /0 C to 40 Safety Approvals Certifications UL 60950-1, CSA C22.2, FCC Class A Warranty Product Warranty 2 years For more information on CyberPower products, visit www.CPSww.com...
  • Page 9: 20A Series

    0 to 95% Non-condensing Altitude 14700 ft/4500 m Temperature F to 104 F /0 C to 40 Safety Approvals Certifications UL 60950-1, CSA C22.2, FCC Class A Warranty Product Warranty 2 years For more information on CyberPower products, visit www.CPSww.com...
  • Page 10: 30A Series

    0 to 95% Non-condensing Altitude 14700 ft/4500 m Temperature F to 104 F /0 C to 40 Safety Approvals Certifications UL 60950-1, CSA C22.2, FCC Class A Warranty Product Warranty 2 years For more information on CyberPower products, visit www.CPSww.com...
  • Page 11: Technical Specifications

    0 to 95% Non-condensing Altitude 14700 ft/4500 m Temperature F to 104 F /0 C to 40 Safety Approvals Certifications UL 60950-1, CSA C22.2, FCC Class A Warranty Product Warranty 2 years For more information on CyberPower products, visit www.CPSww.com...
  • Page 12: Installation Guide

    If you plan on attaching the Cord Retention Tray to the PDU, you will need to use the LONG Mounting Brackets (2). Step 2. PDU Mounting Use the supplied Washers (4) and Screws (4) to secure the PDU to your existing rack system. For more information on CyberPower products, visit www.CPSww.com...
  • Page 13: For 2U Model

    Use the provided Cable Ties to fasten each cord to the Cord Retention Tray. For 2U Model Step 1. Mounting Bracket Installation Use the provided Mounting Bracket Screws (8) to attach the Mounting Brackets (2) to the PDU. For more information on CyberPower products, visit www.CPSww.com...
  • Page 14 Step 3. Cord Retention Tray Installation (optional) Attach the Cord Retention Tray to the PDU with the 8 supplied Cord Retention Tray Mounting Screws. Use the provided Cable Ties to fasten each cord to the Cord Retention Tray. For more information on CyberPower products, visit www.CPSww.com...
  • Page 15: Vertical Installation

    Use the supplied Washers (2) and Screws (2) to secure the PDU to your existing rack system. For 0U Model with Bracket Step 1. Mounting Bracket Installation Use the provided Mounting Bracket Screws (4) to attach the Mounting Brackets (2) to the PDU. For more information on CyberPower products, visit www.CPSww.com...
  • Page 16 Step 3. Cord Retention Tray Installation (optional) Attach the Cord Retention Tray to the PDU with the supplied Cord Retention Tray Mounting Screws. Use the provided Cable Ties to fasten each cord to the Cord Retention Tray. For more information on CyberPower products, visit www.CPSww.com...
  • Page 17: For 0U Model With Keyhole Mount

    Connection to any other type of wall receptacle may result in a shock hazard. Step 2 – Plug the PDU into the wall receptacle For more information on CyberPower products, visit www.CPSww.com...
  • Page 18: Network Installation

    PDU, and the other end to a network port. Step 2 – Establish the PDU IP address Assigning an IP address to the CyberPower PDU requires the user to have an available IP address that is valid on the respective network.
  • Page 19: Operation

    The LED status screen can be set to display upside down from standard through the Web Interface (as shown in figures below). Note: the decimal point will not be moved and will instead be on the top if this option is enabled. For more information on CyberPower products, visit www.CPSww.com...
  • Page 20: Environmental Monitoring (Optional)

    To reset all the settings to default, press and hold the Reset Button for 6 seconds. Remote Management The remote management function of the CyberPower PDU provides for monitoring the PDU vitals, controlling outlets, and utilizing SNMP functionality. Remote management is performed via the web interface. To access the web interface, please follow the instructions below: 1.
  • Page 21: Unattended/Automatic Shutdown

    You can check to see if the firmware upgrade is successful by checking the “Firmware version” on the [System->About] webpage. Note: Please do not turn the PDU off when processing the Firmware upgrade. For more information on CyberPower products, visit www.CPSww.com...
  • Page 22: Troubleshooting

    The Class A digital apparatus meets all requirements of the Canadian Interference- Causing Equipment Regulation. Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada. For more information on CyberPower products, visit www.CPSww.com...
  • Page 23: Customer Service & Warranty

    CyberPower will inspect and examine the Product. If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).
  • Page 24: Appendix A-Hyper Terminal

    2. Time (hh:mm:ss): 17:17:25 3. Name:PDU20SW8FNET 4. Contact: Administrator 5. Location: Server Room [Account Setting] 1. Administrator 2. Viewer(Web Only) [Configure System to Default] Sure to Configure System to Default 1. Yes 0. NO For more information on CyberPower products, visit www.CPSww.com...
  • Page 25: Appendix B-Power Device Network Utility

    Appendix B-Power Device Network Utility • Overview The CyberPower Power Device Network Utility is an easy-to-use interface which is used for establishing IP addresses on CyberPower PDU devices. • Installation Step 1. Insert the CD labeled “PDU Software Installation CD” into the CD/DVD drive.
  • Page 26: Launch Program

    Getting Started The Power Device Network Utility scans the network for devices with MAC addresses that match CyberPower network hardware. Once found, the device(s) can then be figured with a specific IP address, subnet mask, and gateway address. This allows the device(s) to function properly on the network and interface with CyberPower Management Console.
  • Page 27: Advanced Settings

    The timeout function is used to limit the search time. The default setting is 3 seconds. Valid values are 3 to 60 seconds. Figure 8. Timeout Setting For more information on CyberPower products, visit www.CPSww.com...
  • Page 28 CyberPower Systems, Inc. www.CPSww.com K01-0000272-00...

Table of Contents