Kongsberg EK80 Reference Manual
Disassemble the plug.
A
Remove a few
B
millimeters of the
insulation on the
individual cables.
Fold the outer and inner
C
screen backwards, and
fasten them temporary
with tape.
Thread each
D
wire through a
heat-shrinkable tubing,
solder the wire end
to the appropriate pin,
and insulate with the
heat-shrinkable tubing.
E
Remove the tape from
the outer and inner
screen, and spread the
screens out to place
them between the large
washers.
Assemble the plug
F
house, and tighten the
rubber sleeve.