5.6 Temperature graph screen

11:33 – Current time.
201.5 – Temperature value at the point where the vertical dashed line intersects the temper-
ature graph. Touch the line and drag left or right to move across the graph.
DT:30.0 – Temperature delta parameter. Defines vertical scale for temperature. For example,
DT:30.0 means that the display fits temperature within the range
line).
T:203.5/210.0 – current temperature in the chamber (203.5), set value (210.0).
CN: 42/15 – current value of popcorn counter (42), threshold value (15). See "count popcorn"
in Settings screen section.
– press to move in the PID regulator screen (password required).
– press to return to the previous screen.
Scrolling bar in the low part of the screen allows to see the temperature graph changing in time.
Time stamps are marked below the graph.
Figure 14: Temperature graph screen
18