SuperServer SYS-1029UX-LL1-S16/LL2-S16/LL3-S16 User's Manual
E.2 Enabling NVMe RAID
RAID for NVMe SSDs must be enabled through the UEFI BIOS.
1. Install the patch as described in the Restrictions and Requirements section on a
previous page.
2. Reboot the server.
3. Press [DEL] key to enter BIOS.
4. Switch to Advanced > Chipset Configuration > North Bridge > IIO Configuration >
Intel® VMD Technology > CPU1 & CPU2.
5. Enable the VMD according to the following rules.
For U.2 NVMe, enable all the sub-items under each PStack, based on the your model
server:
VMD BIOS Setting for SYS-1029UX-LL1-S16/LL2-S16/LL3-S16
CPU1
VMD Config for PStack0
For M.2 NVMe or NVMe AIC, enable the VMD according to which AOC card/slot it used.
An example U.2 configuration follows.
CPU1 Configuration
Figure E-2. BIOS VMD Setting Example for 24 Drives
CPU2
VMD Config for PStack1
CPU2 Configuration
148