1051 Power Supply Conversion; Dual-Cabinet (Non-Fcc) Installation - Prime Computer 50 Series Service Manual

Table of Contents

Advertisement

Installation
Prime Proprietary
2.7.2 1051 POWER SUPPLY CONVERSION
Convert the 1052 power supply from 225 Vac (60 Hz) to 230 Vac (50
Hz)
service
using
the
following
steps.
Refer to Figure 2~6 during the
procedure.
1
nue
Locate and
remove
the
internal
jumper
cable
(part
number
CBL8259-901) as shown in Figure 2-6.
CAUTION
Failure
to remove/add this jumper when converting to/from
i115 Vac will cause damage to the supply.
Change the jumpers on the terminal strip for 230 Vac operation
as
shown in Figure 2-6.
Change the i5A fuse (SLO-BLO) to 10A (SLO-BIO).
Change the 3A fuse (SLO-BLO) to 2.0A (SLO-BLO)
for
international
operation.
2.8 SYSTEM INSTALLATION
System
installation
procedures are presented in the following order:
@
850 Dual-Cabinet (Non-FCC) Installation
e
850 Dual-Cabinet (FCC) Installation
@
CPU Verification & Top Hat Installation
@
Memory Board Installation Procedure
e@
I/0 Cabling Guidelines
@
1045/1052 Power Supply Installation Verification
@
Uninterruptible Power Supply (UPS) Installation
e@ PDU Cabling
System Console Installation
@
System Configuration
e
Free-Standing Peripheral Cabling
@
Peripheral Equipment Grounding
2.8.3 850 DUAL-CABINET (NON-FCC) INSTALLATION
The 850 system is contained in two cabinets, the Mainbay
cabinet
and
the
I/O
cabinet.
Installation
of
the
cabinets
is
described as
follows.
070-C
2-
12
rel