Primenet Node Controller (Pnc) System - Prime Computer 50 Series Service Manual

Table of Contents

Advertisement

Prime Proprietary
Installation
TABLE 2-35: MDLC CABLE TO BULKHEAD CONFIGURATION (Cont. )
PHYSICAL
BULKHEAD
MDLC
CONNECTOR
BOARD
MDLC
USER
BOARD #
LINE
LINE #
PORT
#
Device
Address
51
D
NOT USED
6
7
J3
7
E
7
8
J2
8
F
NOT USED
2.8.10.12 PRIMENET Node Controller (PNC) System Configuration
The
PNC and PRIMENET software support local ring networks of up to 15
systems.
Systems must be no further than
750
feet
apart
and
each
system
must
have
a
PNC installed.
PRIMENET requires at least Rev.
16.4 PRIMOS.
At Rev.
18.3 PRIMOS, PRIMENET
supports
ring
networks
with
PRIME
and
non-PRIME
systems.
Refer to Figures 2-41 and 2-42
while following the installation procedure below.
SYSTEM |
SYSTEM 2
SYSTEM 3
PRIMENET
PRIMENET
PRIMENET
NODE
NODE
NODE
CONTROLLER
CONTROLLER
CONTROLLER
2257-902
2257-902
2257-902
|
|
|
|
|
|
3288 | CABLEX
pe
|
* CABLE: 3532 — IO FT.
3533 —
3534 —
3535 — SOOFT.
3712 — 7OOFT.
CSO-088
FIGURE 2-41:
PNC INTERCABLING
1.
Each PRIMENET node controller board (2257) should be installed
in
its
respective
system
of the proposed network, according to the
configuration sheet on the side door of the cabinet.
If
no
slot
assignment
has
been
made
for
the
board,
consult your Senior
Customer Service Representative for aid in making the
assignment.
Install
the
PRIMENET
Node
Controller (PNC) board in the proper
slot of each system.
2 - 73