3.4 SYSTEM POWER-DOWN
The system operator or administrator is responsible for
the
system's
power-down.
The
CSR
can
use the following procedure if either the
system administrator
and
operator
are
not
available
during
an
emergency situation or they give their approval.
Power-down 50 series
systems as follows:
@
Shut down the operating system
@
Remove the system's power
These procedures are outlined in the following sections.
3.4.1 OPERATING SYSTEM SHUT-DOWN
The operating system shut-down procedure
is
dependent
upon
whether
PRIMOS
or
PRIMOS
II
is
running.
These
shut-down procedures are
outlined in the following sections.
3.4.1.1 PRIMOS Shut-down Procedure
Before shutting down PRIMOS:
1.
Warn the system and remote system users that the
system
will
be
shut
down,
Messages
are
sent
to
the
users
from the system
console.
The local users are contacted by the following
command:
OK, MESSAGE ALL —NOW
SYSTEM GOING DOWN IN 5 MINUTES.
PLEASE LOGOUT (Control G)
To identify the system names on the network, use the conmand:
OK, STAT NET
Ring Network
Node State
SYSD ReEK
SYSA UP
SYSN DOWN
SYST UP
The
remote
system
users
are contacted by the following command
format:
OK, MESSAGE -1 -NOW -ON <nodename>
System <name> 1s going down in 5 minutes.
2.
Prevent new users from
logging
onto
the
system
by
usingthe__
command :
OK, MAXUSR 0
Setting
MAXUSR to zero does not interfere with users currently on
the system.