Interface Overview - Siemens FIREFINDER-XLS PMI Operation Manual

Table of Contents

Advertisement

PMI OPERATION MANUAL
PMI
Œ
SUPERVISORY
SECURITY
ALARM

POWER
Alarms #
Supers #
Securitys # Troubles #
FIRE ALARM LIST
!
ON
Device custom message
(Currently not used)
10:53
Ž
4
Device custom message
AUDIBLES
10:57
Event Category
(Currently not used)
4
Device custom message
Event Category
(Currently not used)
11:00
4
Device custom message
SILENCED
Event Category
(Currently not used)
11:03
4
Device custom message
Event Category
(Currently not used)
11:06
PARTIAL SYSTEM
Acknowledge
Silence
Unsilence
DISABLED
Alarms
Audibles
Audibles

Figure 1-1
PMI-1 User Interface

Interface Overview

BASIC OPERATION
1-2
TROUBLE

....
Menu

Scroll UP through
the list of events
When lit, provides
More
more information on
Info
+
the highlighted event.
_
Go back to previous screen.

Scroll DOWN through
the list of events
Reset
System
Context sensitive help.
?
PMI-3
ALARM
SUPERVISORY
1
Move one tab left
Move to the left-most tab
2
ALM
MNS2
EMG
MNS1
000
001
000
001
POWER
FIRE ALARM LIST
!
Device custom message
AUDIBLES
10:53
ON
Device custom message
3
SILENCED
10:57
Event Category
Device custom message
PARTIAL
Event Category
11:00
SYSTEM
Device custom message
DISABLED
Event Category
11:03
Device custom message
11:06
Event Category
CPU FAIL
Acknowledg e
Silence
Alarms
Audibles
2
Figure 1-3
PMI-3 User Interface
LEDs blink when an event is reported and unacknowledged (ALARM: red,
SUPERVISORY: yellow, SECURITY (PMI-1/PMI-2 only): yellow, TROUBLE: yellow).
The LEDs glow steady if all events in the class/queue are acknowledged. An
internal audible alarm sounds steady when there is an unacknowledged fire alarm.
It pulses if all alarms are acknowledged, but there is at least one security,
supervisory, or trouble condition.
Along the top and bottom of the LCD are rows of four soft keys. The function of
these keys depends on the screen that is currently displayed. Each of the soft
keys has a green LED that is used to guide the operator to the available actions.
For PMI-3 and the PMI-2 in 'expanded' queue mode, the soft keys at the top of
Œ
ALARM
SUPERVISORY

Alarms #
Supers #
POWER
FIRE ALARM LIST
!
Device custom message
AUDIBLES
10:53
ON
4
Ž
Device custom message
SILENCED
10:57
Event Category
4
Device custom message
PARTIAL SYSTEM
Event Category
11:00
DISABLED
4
Device custom message
Event Category
11:03
4
Device custom message
11:06
Event Category
CPU FAIL
Acknowledge
Silence
Alarms
Audibles

Figure 1-2
PMI-2 User Interface
TROUBLE
Move one tab right
Move to the right-most tab
Menu
SUP
BIDG
TBL
MNST
OTH
001
000
001
000
000
Scroll UP through
MENU
Node X in Control
6
the list of events
4
(Currently not used)
When lit, provides
More
Info
more information on
+
(Currently not used)
5
the highlighted event
8
(Currently not used)
ESC
Go back to previous screen
(Currently not used)
7
?
(Currently not used)
Scroll DOWN through
the list of events
Reset
Unsilence
Audibles
System
Context sensitive help
| CHAPTER 1
PMI-2
SECURITY
TROUBLE

Securitys # Troubles #
Menu
Scroll UP through
the list of events
(Currently not used)
When lit, provides

more information on
(Currently not used)
the highlighted event.
(Currently not used)
Go back to previous screen.
(Currently not used)
Scroll DOWN through
(Currently not used)
the list of events
Reset
Unsilence
Audibles
System
Context sensitive help.

Advertisement

Table of Contents
loading