Radionics recommends testing the
entire system at least once a week,
and having a qualified technician
check the system at a minimum of
once every 3 years.
Suitable for the following applications: 1) Household Burglar Alarm System Units, Grade A. 2) Household Fire Warning System Units. 3) Police Station
connect, Grade A Mercantile Premise alarm system, Grade A Mercantile Safe and Vault alarm system and Grade AA Mercantile Safe and Vault alarm system
when installed in conjunction with Model D8122 derived channel subscriber terminal unit. For all Police Station applications and grades, Model D8108A Attack
Resistant Enclosure with a UL Listed local sounding device is required. 4) Local, Grade A Mercantile Premise alarm system and Grade A Mercantile Safe and
Vault alarm system. For all local applications and grades, Model D8108A Attack Resistant Enclosure and a UL Listed local sounding device is required.
5) Central Station, Grade C application. Central Station, Grade B when installed with a UL Listed local sounding device. Central Station,
Grade AA when installed with Model D8122 derived channel subscriber terminal unit. 6) Proprietary Burglar Alarm units, Grade A.
Proprietary Burglar Alarm unit, Grade BB when installed with the Model D8122 derived channel subscriber terminal unit.
D4412 must be installed in accordance with Installation Instructions 45349.
Do not connect to a receptacle
controlled by a switch. Do not
share with
D4412 uses a
other
CX4010 UL Listed
equipment.
Class 2 Transformer
18 VAC 22 VA 60 HZ
Earth Ground
Green
Data
Yellow
Data
Aux Pwr -
Black
Red
Keypads, Expanders
Printer modules &
Communication modules
Aux
(up to 19 total devices)
Pwr
+
P
P
P
P
S
S
S
S
A
B
C
D
Supervised with 2.2 kΩ
EOL Resistor
(P/N: 47819).
Typical Initiating Devices
are Door Contacts NO/NC,
Floor Mats, Motion
Sensors, Glass Break
Outputs PO3 &
Detectors, etc.
PO4 can sink up
to 500 mA 12
VDC. Use D133/
Maximum charging
D134 for larger
current is 1.1 A.
loads.
BATTERY: Replace
every 3 to 5 years.
Use Radionics' Model
D126, 12 V 7 Amp HR
Output PO2 can be used
Sealed Lead Acid
with Alarm+ as a
Battery for Burglary or
supervised siren driver.
Combination Fire and
Connect an approved
Burglary Systems. For
4 or 8 Ω siren.
additional load or
Alternatively, PO2 can
standby power, refer
sink up to 500 mA 12
to battery calculation
VDC. Use D133/D134
sheet in Installation
for larger loads.
Manual P/N 45349.
* Not investigated by UL.
WARNING: THIS UNIT INCLUDES AN ALARM VERIFICATION FEATURE FOR L-1(LOOP 1)
THAT RESULTS IN A DELAY OF THE SYSTEM ALARM SIGNAL WHEN PROGRAMMED
FOR THIS FEATURE. THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS)
SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING DEVICES SHALL BE
CONNECTED TO L-1 WHEN PROGRAMMED FOR ALARM VERIFICATION, UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
© 2002 Radionics
This system should be installed in accordance with the National Electrical Code, NFPA 70, the National Fire Alarm
Code, NFPA 72 and the local authority having jurisdiction. Depending on the application, the installation is to be in
accordance with one or more of the following UL standards: UL681 Installation and Classification of Mercantile and
Bank Burglar Alarm Systems; UL1076 Proprietary Burglar Alarm Systems and Units; UL1641 Installation and
Classification of Residential Burglar Alarm Systems. Printed information describing proper installation, operation,
testing, maintenance, repair service and response to an alarm is to be provided with this equipment.
Warning: Owner's Instruction Notice: Not to be removed by anyone except occupant.
This equipment has been type tested and found to comply with the specifications in Part 15 of FCC rules for Class B
Computing Devices. Operation is subject to the two following conditions (1) this device may not cause any interference,
and (2) this device must accept any interference received including interference that may cause undesired operation.
Complies with Part 68, FCC Rules. FCC Registration Number: ESVMUL-46531-AL-E
All external connections are inherently Class 2 power limited.
System Delay Chart
Smoke Detector
Circuit
Control Unit
(Loop)
Delay - Sec
Model
Delay - Sec
1
16 sec
(a) The delay (power-up) (start-up) time marked on the
installation wiring diagram of the smoke detector or
on the installed smoke detector(s) is to be used.
Auxilliary Powered Devices 11.5 to 12.4 VDC. Below 10.2 VDC, the D4412 stops processing Loop inputs.
With 7.0 Ah battery,
120 mA for 24 hrs for Fire and Combined Fire/Burglary,
400 mA for 4 hrs for UL Burglary.
600 mA for other*
Include keypads in calculations.
POWER SUPPLY REQUIREMENTS
The Power Supply provides a maximum of 600 mA for the Control Panel
and All Accessory Devices. For System loading, See Installation Manual
P/N 45349. Requirements for battery standby time may reduce
allowable output.
CAUTION: See Manual for power requirements relating to terminals [Alrm+] and [+Aux].
Installer
JP2
Keypad
Connect
Lock
PO1 Terminals can be configured
Installer
as an alarm power output. JP2-
Switch to
PO1 Jumper must be closed.
program.
+
PO1
Alrm
PO4
PO3 PO2
A
B
L-1
+
1
+
see
Note 1
Use compatible
NAC such as
Radionic's D440
400 mA for Fire and
Combined Fire/
Burglary;
1500 mA for UL
P/N
Burglary;
25899
1850 mA for other*
Applies to all four outputs combined.
D6412/D4412 Installation Guide
Installer Switch
Disables Arming,
(a)
Reports, and Relays.
Lock for local
programming.
Note 1: A supervisory alarm output module must be used
on these terminals for household fire applications
Note 2: Jumper J2-PO1 must be in place for connection
to NAC or other powered alarm device.
-
Com
L-2
L-3
Com
L-4
L-5
3
2
4
-
Supervised Loops
Open
7.7 to 14.0 VDC
Normal
6.3 to 7.3 VDC
Powered Sensor Loop
Short
0.0 to 6.0 VDC
suitable for Two-Wire
Smoke Detectors 2.2 kΩ
2.2 kΩ Resistor
Resistor required at End of
(P/N 47819)
Line. For compatible smoke
Required at End of Line
detectors, see Technogram
P/N 46928. The UL Panel
Compatibility Identifier = B. Also available for Four-
Wire Smoke Detectors such as Radionics' D273TH.
Page 63
D6412/D4412
Installation Label
0.1B
See Reference Manual P/N 45349
for System Wiring Diagram
R
R
R1
R1
T1
T1
T
T
Use Radionics
D164
Phone Cord
or equivalent.
Ground Start
requires
D133/D134.
Com
L-6
L-7
Com
L-8
5
6
7
8
Minimum system requirements for Classification in
Accordance with ANSI/SIA CP-01-2000:
UL Listed and Classified control unit Model D4412;
UL Listed and Classified keypad, one or more of
the following:
D621(W), D623(W), D625(W);
UL Listed Local Bell.
This box will be checked if L-1 is
programmed for Alarm Verification.
P/N 50487C 6/02 2002 © Radionics
Red
Gray
Premises
Brown
Phone
Green
Incoming
Phone
Line
45349D