2.3.3

Communicator

The panel uses a built-in digital communicator to send reports to the receiver. The panel transmits reports in
either Modem IIIa², Contact ID or Pager format.
Only the following Central Station Receivers support the panel's Modem IIIa
• D6600 with CPU v01.01.03 (or higher)
• D6500 with D6511 MPU v1.05 (or higher)
The D6500 with D6510 MPU does not support the panel's Modem IIIa
IMPORTANT
The panel connects to an RJ31X jack for phone line seizure. Connection to the RJ31X complies with FCC
regulations for using the public telephone network. You can program the panel to route reports to one of two
routing destinations.
The system has routing capabilities that allow you to direct groups of system event reports and individual point
reports to two different routing destinations. The reports can be routed to either destination, both destinations, or
to Destination 2 only on failure of Destination 1.
Each routing destination can be programmed with two phone numbers.
Check panel communications (from panel to Central Station) to verify that the panel is communicating
properly in the selected reporting format at least once annually.
IMPORTANT
2.3.4

Command Centers

You can connect a maximum of 8 fully supervised Command Centers to the system. The available power affects
the total number of Command Centers you can connect without providing an auxiliary power supply.
The panel transmits a serial device trouble report, SDI MISSING in the Modem IIIa² format or Sys
Peripheral Trouble in the Contact ID format, if it loses communication with a Command Center. Table 3
shows the Command Centers compatible with the panel. See Command Center in the D6412/D4412 Program
Entry Guide (P/N: 45351) for complete details on programming Command Center options.
2.3.5

Keyswitch

You can arm and disarm any of the available areas with maintained or momentary closure devices such as
keyswitches. Point programming determines loop responses and which area a keyswitch controls. Sub-control
units (D279) can arm and disarm individual points.
2.3.6

Alarm Event Memory

The system uses alarm event memory to store alarm events for each area. You can view the area alarm events
at a Command Center assigned to the area. The panel clears the area's alarm event memory and starts storing
new alarm events when you turn the area On.
2.3.7

Event Log

The system stores 254 events from all areas in its event log.
All events can be stored even if the panel does not send a report for them. You can view the log at a text
Command Center (the D623 for example), print it locally using the DX4010 Serial Interface Module and a serial
printer, or upload it to the Remote Account Manager (RAM IV).
See Appendix B in the D6412/D4412 Program Entry Guide (P/N: 45351) for a listing of log events and how to
view them.
© 2002 Radionics
Model
D621
D623
2 lines of 16 characters, LCD
D625
2 lines of 16 characters, vacuum fluorescent

Table 3: Compatible Command Centers

D6412/D4412 Installation Guide
Page 13
2
2
Format.
Display
16-Point LED
D6412/D4412
Overview
Format:
45349D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Radlonlcs d4412

Table of Contents