5   OPERATION
Stick (SMAW)
The polarity changeover cable is used to select the correct polarity for the weld output. The correct
polarity is determined by the wire that has been selected to complete the weld. To configure the
machine to operate with electrode positive insert and secure the polarity changeover cable into the
positive [+] terminal and the return lead into the negative [-] terminal. Be sure that the connections are
tight. Secure the work clamp to the work piece in a clean, debris free location.
Secure the work clamp to the work piece in aclean, debris free location.
NOTE!
Some wires it is recommended to use negative polarity such as self-shielded flux-core. See
wire manufacturers recommendation.
5.3

Drive system diagram

1. Wire inching/purge
2. Wire feed mechanism
0447 978 001
Live GTAW
3. Wire spool