PROGRAMMING DOWN TRAVEL LIMIT
WARNING
!
Make sure doorway is in full view and clear of obstacles and people to
avoid injury or property damage.
DO NOT operate this unit from the wall control before LIMITS are set.
Severe damage to the operator could occur.
The carriage MUST be engaged to turnbuckle BEFORE setting limits. See
DO NOT set limits with Battery Backup attached. AC power MUST be
connected to the operator while setting limits for proper operation .
AVERTISSEMENT
!
S'assurer que le passage de la porte est visible et dégagé, à savoir
sans obstacles ni personne afin d'éviter toute blessure potentielle ou
dommage matériel.
NE PAS utiliser cette unité avec la console murale avant d'avoir réglé les
LIMITES. L'ouvre-porte pourrait subir de sérieux dommages.
La tendeur DOIT être engagée dans le chariot AVANT de régler les
limites. Voir le poster d'installation (si fourni) ou appelez le service
clientèle au 1-800-35-GENIE ou visitez le site www.geniecompany.com.
NE PAS fixer de limites en mode batterie de secours. L'alimentation CA
DOIT être branchée sur l'ouvre-porte, pendant le réglage des limites,
pour assurer un bon fonctionnement.
NOTE: Carriage should be locked to belt/chain rail. Door
should rest somewhere between full open and closed. Do not
start with door fully open or closed.
Programming DOWN Limit:
1. Press and hold the DOWN arrow button.
· Long LED will light BLUE.
2. Release DOWN arrow button.
· Long LED will flash BLUE.
3. Press and hold the DOWN arrow button
until door is fully closed.
· Use the UP arrow button if door closes
too far. Use both UP and DOWN buttons
to adjust close travel as necessary.
NOTE: Door should rest on the floor until the
weather strip is compressed enough to seal
along the width of the door. Damaged doors
or uneven floors may not seal properly. Repair
these conditions to achieve a proper seal. DO
NOT compress seal so much that the door will
bend or buckle.
4. Press and release the SET/PRGM button
· Both LEDs will flash BLUE then go out.
The DOWN limit is now programmed.
1-2. Enter Programming Mode
PRGM
Steady Blue
SET
Flashing
PRGM
Blue
SET
3. Adjust Door Position
PRGM
SET
4. Lock Programming
Flashing Blue
HOLD
UNTIL
LED
Lights
RELEASE
PRGM
SET
PRESS
&
RELEASE
PRGM
SET