Wired Safety Edge Instructions (Optional) - Genie GCL-LT Manual

Light-duty trolley operator for sectional doors
Table of Contents

Advertisement

INSTALL AND WIRE MONITORED SAFETY DEVICE

Wired Safety Edge Instructions (Optional)

Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
L'activation de l'operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d'inversions externes, y compris les systèmes de détection des bords.
MillerEdge® "DC" Series & ASO Monitored Sensing Edge
Installation with Interface Module
Right-hand installation shown, left-hand installation mirrored
1. Mount junction box to wall one half the door height plus 12" from floor.
2. Install hard-wiring from operator and coil cord to junction box and secure with conduit clamps.
3. Connect hard-wiring from operator to coil cord with wire nuts and install junction box cover plate. These
are not polarity sensitive.
4. Install wires to STB terminals in operator.
5. Attach coil cord to monitored edge interface module in junction box as shown and secure with conduit
clamps.
6. Install wires from monitored edge to interface module as shown below.
7. Install cover plate.
NOTE: DO NOT use take up reels with monitored edge systems
WARNING
!
AVERTISSEMENT
!
Operator Terminal Strip
Operator Terminal Strip
T3 Safety Edge
T3 Safety Edge
Junction
Box
Junction
Black
Box
Interface Module
Black
1/2 Door Height
+ 12in.
Monitored
1/2 Door Height
Safety Edge
+ 12in.
Monitored
Safety Edge
MillerEdge®
Interface Module
Install
Red
MillerEdge®
COIL
CORD
Install
Red
COIL
CORD
Red
White
Red
White
19