Handling The High-Pressure Hose; Interruption Of Work; Cleaning The Device; Cleaning The Unit From The Outside - WAGNER TempSpray-H126 Operating Manual

Hide thumbs Also See for TempSpray-H126:
Table of Contents

Advertisement

Available languages

Available languages

TempSpray-H326 / -H226 / -H126
5
HANDLING THE HIGH-PRESSURE
HOSE
Danger of injury through leaking high-
pressure hose. Replace any damaged high-
pressure hose immediately.
Never repair defective high-pressure hoses
yourself!
The high-pressure hose can't be removed
from the hose reel or the controller housing.
Never try to loosen the connection.
The high-pressure hose is to be handled with care. Avoid sharp
bends and folds: the smallest bending radius is about 20 cm.
Do not drive over the high-pressure hose. Protect against
sharp objects and edges.
Never pull on the high-pressure hose to move the device.
Always unroll the high-pressure hose com-
pletely.
When using the high-pressure hose while
working on scaffolding, it is best to always
guide the hose along the outside of the scaf-
folding.
The risk of damage rises with the age of the
high-pressure hose.
Wagner recommends replacing high-pressu-
re hoses after 6 years.
Only use WAGNER original-high-pressure
hoses with internal heating in order to ensure
functionality, safety and durability.
6

INTERRUPTION OF WORK

Release the pressure in the hose and switch off the heating
during longer breaks.
In using quick-drying or two-component
coating materials, do not fail to rinse unit
through with a suitable cleaning agent dur-
ing the processing period.
Important: The application life of the material
can change as a result of heating. Therefore,
please consult the material manufacturer.
HANDLING / INTERRUPTION OF WORK / CLEANING / SERVICING
7

CLEANING THE DEVICE

A clean state is the best method of ensuring operation with-
out problems. After you have finished spraying, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit.
Clean the device with an adequate detergent, after finishing
the paint work.
The solvent used for cleaning (with a flash point over 21 °C)
has to be adequate to the coating material.
While cleaning with solvents (except water)
-> always switch off heating.
Do not put the high-pressure hose into sol-
vents. Use only a wet cloth to wipe down the
outside of the hose.
The container must be earthed in case of
coating materials which contain solvents
(except water).
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safety regulations.
When cleaning without a nozzle, reduce the
pressure to approx. 20 bar.
Warm water improves the cleaning effect in
the case of water-dilutable coating materials.
Therefore the heating can stay switched on.
7.1

CLEANING THE UNIT FROM THE OUTSIDE

First unplug the power plug from the outlet.
Danger of short-circuits caused by water
ingression! Never spray down the unit with
high-pressure or high-pressure steam clean-
ers.
Wipe unit externally with a piece of cloth, which has been im-
mersed in a suitable cleaning agent.
EN
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tempspray-h226Tempspray-h326

Table of Contents