REMEDY IN CASE OF FAULTS

DISPLAYED ERROR CODE
Err0
Err1
Err2
Err3
Err4
Err5
Temperature is displayed
in °F instead of °C
In the case of all abovementioned errors, a
task that has been started can still be fin-
ished with the TempSpray heating system
switched off.
POSSIBLE CAUSE
Residual current exceeded (approx. 33mA) and
relay cuts out:
Heating conductor insulation in hose dam-
aged
Cable has come loose
Water has penetrated device
Electronics defective - no communication be-
tween the boards
Control board does not receive any feedback
Interface board does not receive any feedback
/no information is received by the interface
board
Cables pinched in housing
Heating resistance too large:
Current flow in heating conductor is inter-
rupted
Overtemperature protection has actuated
Heating resistance too small:
Short-circuit in heating wire
Temperature display converted to Fahrenheit
MEASURES FOR ELIMINATING THE MALFUNCTION
Please contact Wager Customer Service
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Have a skilled electrician open the housing
and check the cables.
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Disconnect the device from the power supply.
Wait approx. 30 seconds and switch it back on.
If the error code is still displayed, contact Wag-
ner Customer Service.
Press „START" and „
" simultaneously to con-
vert the display to °C.