10 Electrical connection

The appliance complies with the actual directives. The installation must continue to comply with:
- A 230V -50Hz mains electrical supply is required fused externally at 3A.
- A deviation on the grid of 230V (+10% or -15%) and 50Hz
- the national rules for electrical installations.
The appliance must be connected to an earthed socket. This must be visible and within reach.
The following general stipulations also apply:
- No changes may be made to the wiring of the appliance;
- All connections should be designed in accordance with the enclosed regulations;
- Should it be necessary to change it, the mains power supply cable may only be replaced with an ATAG
mains power supply cable.
The connection terminals are positioned at the back of the control unit:
- Press handle A slightly to the left (see fig. 10.a)
- Turn the control unit downwards.
terminal block
30
A
Terminal block iR-Range
n.a. = not applicable
n.a. = not applicable
n.a. = not applicable
n.a. = not applicable
n.a. = not applicable
n.a. = not applicable
230V control terminal block iR-Range
SwL:
Switched live
SwL
L:
Live
L
N:
Neutral
N
E:
Earth
E
L':
Live pump
L'
N':
Neutral pump
N
E
E':
Earth pump
Installation & Servicing instructions ATAG iR-Range
230V live input only!
230V live output
230V live output
to pump
Figure 10.a