Setting the BIOS Configuration Jumper

CAUTION
Always turn off the power and unplug the power cord from the server before changing the jumper.
Moving the jumper with the power on may result in unreliable server operation.
3
1
J9G2
This three-pin jumper block, shown in Figure 19, enables all server board configurations to be
done in BIOS Setup. Table 5 shows the jumper settings for the Setup program modes.
Table 5.

Jumper Settings for the BIOS Setup Program Modes

Function/Mode
Normal
Configure
Recovery
Upgrading
Figure 19. BIOS Configuration Jumper Block Location
Jumper Setting
Configuration
1-2
The BIOS uses current configuration information and passwords
3
1
for booting.
2-3
After the POST runs, Setup runs automatically. The maintenance
3
1
menu is displayed.
None
The BIOS attempts to recover the BIOS configuration. A
3
1
recovery diskette is required.
OM12206
35