Function
Sequence of operations 1. Enter the menu by typing the user or supervisor code.
20230503-V0

7.9. Limit output state display mode (12. menu item)

The state of limit outputs may present on the display. Here
you can set the condition of presenting the states. [Factory
default: dynamic]
The way the code should be type in is described in Chapter
7.1. You see this on the display:
2. Keep stepping by pressing the ▲ button as long as you
see this menu item:
displaying).
3. Enter the menu item by pressing the ENTER button.
4. You see this on the display:
blinking, signaling that it can be modify.
5. Pressing ▲ button select the displaying mode.
You can choose from the following:

(Dynamic = dynamic)
It displays the limit output state as far as the ENTER button
is pressed. [Factory default]

(Timed = timed)
It displays the limit output state as far as the ENTER button
is pressed and 2.5 sec. long after releasing button.

(Static = static)
Pressing ENTER button the limit output display can be
switch on or switch off.

(Changing = changing)
Changing the state any of the limit outputs (switch on or
switch off) it displays the state automatically for 2.5 sec.
long.
Keeping the ENTER button pressed it displays the
measuring value.

(Periodical = periodical)
It changes between the limit display and measuring display
mode in 2.5 sec. period.
Keeping the ENTER button pressed it displays the
measuring value.


(Limit Displaying = limit

.
. The mnemonic is