WAGO Kontakttechnik GmbH & Co. KG declines all liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this manual.
More information References on additional literature, manuals, data sheets and INTERNET pages 1.3 Number Notation Number Code Example Note Decimal normal notation Hexadecimal 0x64 C notation Binary '100' Within ', '0110.0100' Nibble separated with dots WAGO-I/O-SYSTEM 751 AS-Interface Components IP67...
IP67 degree of protection! 1.5 Scope This manual describes the Digital Input Module 751-3001 AS-Interface Module 4IN 24V Single of the modular WAGO-I/O-SYSTEM 751. Handling, assembly and start-up are described in the manual of the Fieldbus Coupler. Therefore this documentation is valid only in the connection with the appropriate manual.
The sensors are connected using M12x1 round plugs. The AS-Interface cable can be connected directly. LEDs indicate the status of inputs and outputs, the AS-Interface and actuator supply as well as a short circuit or overload condition. WAGO-I/O-SYSTEM 751 AS-Interface Components IP67...
The PGM connection is the programming connector. It is a plug for a DC socket, which is compatible with all popular programming adapters, for example Pepperl+ Fuchs VAZ-PK-1.5M-V1-G. Please note manufacturer documentation for the operation of the programming device. WAGO-I/O-SYSTEM 751 AS-Interface Components IP67...
AS-Interface supply OK supply 2.1.1.5 Operating Elements Above the programming connector is an infrared sensor for communication with a programming device with optical interface. Please note manufacturer documentation for the operation of the programming device. WAGO-I/O-SYSTEM 751 AS-Interface Components IP67...
3. Fix the upper part in the snap-in position of the ground plate. 4. Push the upper part onto the ground plate. Tighten screws of the upper part with a tightening torque of 0.9N m. Electrical contact with the conductors is made automatically. Fig. 2.1.1-7: Assembly gqxxx10x WAGO-I/O-SYSTEM 751 AS-Interface Components IP67...
AS-Interface specification may lead to malfunctions or restrictions. Please note the AS interface master manual and the manual for the start-up tool WAGO-I/O-CHECK 2 (759-302) for start-up and diagnosis of the AS interface slaves with AS interface master 750-655 from the WAGO-I/O- SYSTEM 750.
Need help?
Do you have a question about the I/O-SYSTEM 751-3001 and is the answer not in the manual?
Questions and answers