Ac Voltage Measurement; Ac+Dc Voltage Measurement - AEMC 205 User Manual

Power clamp-on meter
Table of Contents

Advertisement

4.2.2

AC Voltage Measurement

Measurement
Range
Specified
Measurement
(2)
Range
Accuracy
Resolution
Input Impedance
Note (1)
The display indicates "OL" above 1000V (1400V in PEAK mode).
Above 1000V (RMS), a repetitive beep indicates that the voltage
being measured is greater than the safety voltage for which the
device is guaranteed. The display indicates "OL".
- Bandwidth in AC = 3 kHz
Note (2)
Any value between zero and the min. threshold of the measurement
range (0.15V) is forced to show "----" on the display.
Specific Specifications in MAX/MIN mode
(from 10Hz to 1kHz, and from 0.30V in AC):
Accuracy: add 1% R to the values of the table above.
Capture of the extreme: approximately 100ms.
4.2.3

AC+DC Voltage Measurement

Measurement Range (2)
Specified Measurement
Range
Accuracy
Resolution
Input impedance
Note (1)
The display indicates "OL" above 1000V (1400V in PEAK mode).
Above 1000V (DC or RMS), a repetitive beep indicates that the
voltage being measured is greater than the safety voltage for which
the device is guaranteed.
- Bandwidth in AC = 3 kHz
Note (2) Any value between zero and the min. threshold of the measurement
range (0.15V) is forced to "----" on the display.
0.15 to
59.99V
0 to 100% of the measurement range
0.15 to 5.99V
± (1% R +10cts)
6.00 to 59.99V
± (1% R +3cts)
0.01V
0.15 to
59.99V
0 to 100% of the measurement range
0.15 to 5.99V
± (1% R +10cts)
6 to 59.99V
± (1% R +3cts)
0.01V
60.0 to
599.9V
± (1% R +3cts)
0.1V
10MΩ
60.0 to
599.9V
0.1V
10MΩ
36
600V to 1000V RMS
1400V peak
1V
600V to1000V RMS
1400V peak
± (1% R +3cts)
1V
(1)
(1)

Advertisement