True Inrush ® Measurement; Continuity Measurement; Resistance Measurement - AEMC 601 User Manual

Clamp-on meter
Table of Contents

Advertisement

Specific Specifications in MAX/MIN mode (from 10Hz to 1kHz, and from
0.30A in AC):
Accuracy (with zero corrected): add 1% R to the values of the table
above.
Capture of the extreme: approximately 100ms.
4.2.4
True Inrush
Measurement range
Specified measurement range
Accuracy
Resolution
Specific Specifications in PEAK mode in True InRush (from 10Hz to 1kHz):
Accuracy: add ± (1.5% R +0.5A) to the values in the tables above.
PEAK capture time: 1ms min. to 1.5ms max.
4.2.5

Continuity Measurement

Measurement range
Open-circuit voltage
Measurement current
Accuracy
Buzzer triggering threshold
4.2.6

Resistance Measurement

Measurement range (1)
Specified measurement
range
Accuracy
Resolution
Open-circuit voltage
Measurement current
Note (1) Above the maximum display value, the display unit indicates "OL".
The "-" and "+" signs are not displayed.
Specific Specifications in MAX/MIN mode:
Accuracy: add 1% R to the values of the table above.
Capture of the extreme: approximately 100ms.
®
Measurement
0 to 100% of the measurement range
Adjustable from 1 to 999Ω (40Ω is the default)
0.0 to
999.9Ω
1 to 100% of the
measurement range
0.1Ω
550µA
20 to 2000A
± (5% R + 5cts)
1A
0.0 to 999.9Ω
≤ 3.6V
550µA
± (1% R +5cts)
1000 to
9999Ω
± (1% R +5cts)
≤ 3.6V
100µA
30
AC
10.00 to
99.99kΩ
0 to 100% of the
measurement range
1Ω
10Ω
10µA