Electrical Safety; Specific Safety Instructions - Internal Vibrators - Wacker Neuson IREN Operator's Manual

Internal vibrator
Table of Contents

Advertisement

In the case of extensive work with this machine, long-term vibration-induced damage cannot be ruled
out. For exact values of vibration measurement, refer to the Technical Data section.
Wear suitable clothing. Keep loose clothing, gloves, jewelry, and long hair away from moving/rotating
machine parts. Danger of being pulled!
Ensure that no other individuals are in the danger zone!
3.6.4
Handling and use
Handle machines with care. Do not operate machines with defective components or operator's
controls. Immediately replace defective components or operator's controls. Machines with defective
components or operator's controls carry a high risk of injury!
The operator's controls of the machine shall not be improperly locked, manipulated, or changed.
The machine, accessories, and tools should be used in accordance with these instructions.
Store unused machines out of reach of children. The machine may only be operated by authorized
personnel.
After operation, store the cooled-down machine in a locked, clean, frost-protected, and dry location
that is inaccessible to children and other unauthorized individuals.
3.7

Electrical safety

3.7.1
Electric power supply for machinery of class rating I
The internal vibrator must be connected to a plug receptacle with a protective earth contact 15 A/16 A
with the corresponding overload fuse protection.
One of the following protective ground fault interrupters is necessary:
Standard protective ground fault interrupter (pulse current sensitive, type A).
All current sensitive protective ground fault interrupter (type B).
Only connect to electric power supplies if all machine parts are in a technically perfect condition.
The electric power supply must exhibit an intact grounded conductor connection (PE) and a protective
earth contact 15 A/16 A and corresponding overload fuse protection.
When connecting to fixed or mobile power units, at least one of the following safety devices must be
present:
Protective ground fault interrupter (GFI or GFCI).
Insulation monitor.
IT net.
When connecting a job site electrical distributor, it must be grounded!
Observe the respective national safety standards!
3.7.2
Extension cable
Do not operate the machine with damaged extension cables.
Use extension cables with grounded conductors and the correct grounded conductor terminal to plug
and coupling.
Only use tested extension cables! For job site use, Wacker Neuson H07RN-F, H07BQ-F, a SOOW-
cable or a country-specific equivalent design are recommended.
Cable drums and multi-pole plug receptacles must meet the same requirements as extension cables.
Protect extension cable, multi-pole plug receptacles, cable drums and connection couplings from
rain, snow or other forms of moisture.
3.8
Specific safety instructions – Internal vibrators
3.8.1
External influences
The internal vibrator may not be operated under the following external influences:
In heavy rain on sloped surfaces. Risk of slipping!
In potentially explosive areas. Explosion hazard!
3.8.2
Operational safety
Pay maximum attention near drops or slopes, to scaffolding and ladders. Risk of crashing!
Check the load-bearing capacity of the soil and protection of walls and ceilings.
The operator must not leave the machine while it is in operation.
Do not leave the machine unattended. Risk of injury!
Protect the machine from unauthorized operation.
Delimit spacious workspace and restrict access to unauthorized individuals. Risk of injury!
100_0101_si_0010.fm
3 Security
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iren30Iren38Iren45Iren58Iren65

Table of Contents