Control - Introduction

Display unit

2023-06-08
A
B C D E
A
DISPLAY
Instructions, settings and operational information are
shown on the display.
B
STAND-BY BUTTON
F110 can be switched to stand-by mode using the
standby button. The compressor, immersion heater and
fan are then switched off. Press the button for three
seconds to activate/deactivate standby mode.
C
BACK BUTTON
The back button is used to:
go back to the previous menu.
change a setting that has not been confirmed.
D
OK BUTTON
The OK button is used to:
confirm selections of sub menus/options/set values.
E
UP AND DOWN BUTTONS
With the up and down buttons you can:
scroll in menus and between options.
increase and decrease the values.

Menu system

When F110 is started you come to the information menu.
Basic information about the heat pump status is shown here.
Date
2023-06-08
Status icons
NIBE F110
08:15
Clock
08:15
Hot water temp.
The information menu shows:
on starting.
when the back button in the main menu is pressed.
after 15 minutes of inactivity.
Press any button to go to the main menu.
MAIN MENU
ventilation
HOT WATER
INFO
MY SYSTEM
The menu system's main menus are shown here.
MENU 1 - VENTILATION
Setting the ventilation. See page 25.
MENU 2 - HOT WATER
Setting and scheduling hot water production. See page 26.
MENU 3 - INFO
Display of temperatures and other operating information
and access to the alarm log. See page 28.
MENU 4 - MY SYSTEM
Setting time, date, language, operating mode etc. See page
29.
MENU 5 - SERVICE
Advanced settings. These settings are not available to the
end user. Go to the main menu and hold the Back button
pressed in for 7 seconds to access the Service menu. See
page 30.