Control - Introduction

Display unit

INDOOR CLIMATE
HOT WATER
HEAT PUMP
INFO
F370
A
DISPLAY
Instructions, settings and operational information are
shown on the display. You can easily navigate between
the different menus and options to set the comfort or
obtain the information you require.
B
STATUS LAMP
The status lamp indicates the status of the heat pump.
It:
lights green during normal operation.
lights yellow in emergency mode.
lights red in the event of a deployed alarm.
C
OK BUTTON
The OK button is used to:
confirm selections of sub menus/options/set val-
ues/page in the start guide.
D
BACK BUTTON
The back button is used to:
go back to the previous menu.
change a setting that has not been confirmed.
E
CONTROL KNOB
The control knob can be turned to the right or left. You
can:
scroll in menus and between options.
increase and decrease the values.
change page in multiple page instructions (for example
help text and service info).
F
SWITCH (SF1)
The switch assumes three positions:
On ( )
Standby (
)
Emergency mode (
Emergency mode must only be used in the event of a
fault on the heat pump. In this mode, the compressor
switches off and the immersion heater engages. The heat
pump display is not illuminated and the status lamp illu-
minates yellow.
G
USB PORT
The USB port is hidden beneath the plastic badge with
the product name on it.
The USB port is used to update the software.
Visit
nibeuplink.com
download the latest software for your installation.
38
Chapter 7 | Control - Introduction
A
Display
B
Status lamp
C
OK button
D
Back button
E
Control knob
F
Switch
G
USB port
) (see page 48)
and click the "Software" tab to

Menu system

When the door to the heat pump is opened, the menu sys-
tem's four main menus are shown in the display as well as
certain basic information.
Outdoor
Indoor temperature - (if room sensors are
temperature
installed)
INDOOR CLIMATE
HOT WATER
SERVICE
HEAT PUMP
Temporary lux (if activated)
MENU 1 - INDOOR CLIMATE
Setting and scheduling the indoor climate. See information
in the help menu or user manual.
MENU 2 - HOT WATER
Setting and scheduling hot water production. See informa-
tion in the help menu or user manual.
MENU 3 - INFO
Display of temperature and other operating information and
access to the alarm log. See information in the help menu
or user manual.
MENU 4 - HEAT PUMP
Setting time, date, language, display, operating mode etc.
See information in the help menu or user manual.
MENU 5 - SERVICE
Advanced settings. These settings are not available to the
end user. The menu is visible when the Back button is
pressed for 7 seconds when you are in the start menu. See
page 44.
Hot water temp.
Information about
operation
INFO
Estimated amount of hot
water
NIBE F370