Technical Specifications - Nibe F110 Installation Manual

Hot water heat pump
Hide thumbs Also See for F110:
Table of Contents

Advertisement

Technical specifications

1x230 V
Output data according to EN 16 147
Capacity (P
)/COP
H
Additional power
Output immersion heater
Electrical data
Rated voltage
Max operating current
Min. fuse rating
Driving power circulation pump
Driving power fan
Enclosure class
Ventilation
Filter type, exhaust air filter
Refrigerant circuit
Type of refrigerant
GWP refrigerant
Volume
CO
equivalent
2
Cut-out value pressostat HP
Air flow requirement
Min. airflow with the temperature of the incoming air below
10 °C
Min. airflow with the temperature of the incoming air at least
10 °C
Temperature range for compressor operation
Sound effect level according to EN 12 102
4
Sound power level (L
)
W(A)
Sound pressure levels according to EN ISO 11 203
Sound pressure level in the installation room (L
Pipe connections
Hot water ext Ø
Cold water ext Ø
Safety valve ext. Ø
Ventilation ext Ø
Filter box ext. Ø
1 A20(12), luftflöde 50 l/s (180 m
2 A7(6), luftflöde 70 l/s (250 m
3
/h)
3 A20(12), luftflöde 50 l/s (180 m
4 The value varies with the fan speed selected. For more detailed sound data, including sound to ducts, visit nibe.eu.
5 The value can vary with the room's damping capacity. These values apply at a damping of 4 dB.
NIBE F110
5
)
P(A)
3
/h)
3
/h)
Exhaust air
1
kW/-
1.32 / 2.89
kW
V
A
A
W
W
kg
ton
MPa/bar
l/s
-
l/s
25
°C
10 - 37
dB(A)
dB(A)
mm
mm
mm
mm
mm
Outdoor air
Surrounding air
2
1.08 / 2.36
1.32 / 3.27
1.3
230 V ~ 50 Hz
9.1
10
5-20
20-75
IPX1B
Coarse 65%
R134A
1430
0.38
0.54
2.2 / 22.0
83
-
42
25
-10 - 37
10 - 37
47.0
43.0
22
22
15
160
160/125
Chapter 12 | Technical data
3
37