Disturbances In Comfort; Info Menu; Manage Alarm; Troubleshooting - Nibe F110 Installation Manual

Hot water heat pump
Hide thumbs Also See for F110:
Table of Contents

Advertisement

Disturbances in comfort

In most cases, F110 notes a malfunction (a malfunction can
lead to disruption in comfort) and indicates this with alarms,
and instructions for action, in the display.

Info menu

All the heat pump measurement values are gathered under
menu 3.1 in the heat pump menu system. Looking through
the values in this menu can often simplify finding the source
of the fault. See help menu or user manual for more inform-
ation about menu 3.1.

Manage alarm

alarm 291
charge pump
aid mode
reset alarm
no
In the event of an alarm, a malfunction has occurred, which
is indicated by an alarm symbol in the display.
ALARM
In the event of an alarm a malfunction has occurred that
F110 cannot rectify itself. The display shows what type of
alarm it is and lets you reset the alarm. You can also choose
to set the heat pump to rescue mode
reset alarm In many cases it is sufficient to select "reset
alarm" to correct the problem that caused the alarm. If the
alarm recurs, the problem that caused the alarm remains.
If the alarm disappears and then recurs, see the
troubleshooting section (page 33).
aid mode "aid mode" is a type of emergency mode. This
means that the heat pump produces hot water despite there
being some kind of problem.
This can mean that the heat pump's compressor is not run-
ning. In this case the immersion heater produces hot water.
Caution
Selecting "aid mode" is not the same as correcting
the problem that caused the alarm. The alarm
symbol will remain displayed.

Troubleshooting

If the operational interference is not shown in the display
the following tips can be used:
NIBE F110
yes
BASIC ACTIONS
Start by checking the following items:
That the feed cable is connected to F110.
Group and main fuses of the accommodation.
The property's earth circuit breaker.
Heat pump's earth-fault breaker.
Temperature limiter for F110 (FQ10).
LOW HOT WATER TEMPERATURE OR A LACK OF
HOT WATER
Large hot water consumption.
Wait until the hot water has heated up. Temporarily in-
creased hot water capacity (temporary lux) can be ac-
tivated in menu 2.1.
Too low hot water setting.
Enter menu 2.2 and select a higher comfort mode.
Filter clogged (installation with ambient air)
Clean or replace the filter.
Thermostat setting too low (BT35)
Turn the thermostat to max.
Low or a lack of ventilation (exhaust air installation)
See section "Low or a lack of ventilation".
Applies to incoming air blocked (outdoor air installation)
Clean the grille.
LOW OR NO VENTILATION (EXHAUST AIR
INSTALLATION)
Filter (HQ12) blocked.
Clean or replace the filter.
The ventilation is not adjusted.
Order/implement ventilation adjustment.
Exhaust air device blocked or throttled down too much.
Check and clean the exhaust air devices.
Fan speed in reduced mode.
Enter menu 1 and select "normal".
HIGH OR DISTURBING VENTILATION (EXHAUST
AIR INSTALLATION)
Filter (HQ12) blocked.
Clean or replace the filter.
The ventilation is not adjusted.
Order/implement ventilation adjustment.
Fan speed in forced mode.
Enter menu 1 and select "normal".
Chapter 10 | Disturbances in comfort