Menu 2 - HOT WATER

OVERVIEW
2 - HOT WATER
* Accessory needed.
Sub-menus
For the menu
HOT WATER
Status information for the relevant menu can be found on
the display to the right of the menus.
temporary lux
Activation of temporary increase in the hot
water temperature. Status information displays "off" or what
length of time of the temporary temperature increase re-
mains.
comfort mode
Setting hot water comfort. The status inform-
ation displays what mode is selected, "economy", "normal"
or "luxury".
scheduling
Scheduling hot water comfort. Status informa-
tion "active" displays if the scheduling is active right now,
the status information "set" displays if the scheduling is set
but not active.
advanced
Setting periodic increase in the hot water tem-
perature.
MENU 2.1 - TEMPORARY LUX
Setting range: 3, 6 and 12 hours and mode "off" and "one
time increase"
Default value: "off"
When hot water requirement has temporarily increased this
menu can be used to select an increase in the hot water
temperature to lux mode for a selectable time.
26
Chapter 8 | Control - Menus
2.1 - temporary lux
2.2 - comfort mode
2.3 - scheduling
2.9 - advanced
there are several sub-menus.
2.9.1 - periodic increase
Caution
If comfort mode "luxury" is selected in menu 2.2
no further increase can be carried out.
The function is activated immediately when a time period
is selected and confirmed using the OK button. The remain-
ing time for the selected setting is shown to the right.
When the time has run out F110 returns to the mode set in
menu 2.2.
Select "off" to switch off
temporary lux
MENU 2.2 - COMFORT MODE
Setting range: economy, normal, luxury
Default value: normal
The difference between the selectable modes is the temper-
ature of the hot tap water. Higher temperature means that
the hot water lasts longer.
economy: This mode produces less hot water than the oth-
ers, but is more economical.
normal: Normal mode gives a larger amount of hot water
and is suitable for most households.
luxury: Lux mode gives the greatest possible amount of hot
water. In this mode, the immersion heater is used to heat
hot water as well as the compressor, which increases oper-
ating costs.
MENU 2.3 - SCHEDULING
Activated
activated
all
mon
tues
wed
thur
fri
sat
sun
Day
Time period
What hot water comfort the heat pump is to work with can
be scheduled here.
.
scheduling 2.3
05:30
06:00
economy
05:30
06:00
economy
05:30
06:00
economy
06:00
economy
05:30
05:30
06:00
economy
05:30
06:00
economy
05:30
06:00
economy
Comfort mode