SYSTEM DIAGRAM
F110 consists of a heat pump, water heater, immersion
heater and control system.
When the air passes through the evaporator, the refrigerant
evaporates because of its low boiling point. In this way the
energy in the air is transferred to the refrigerant.
The refrigerant is then compressed in a compressor, causing
the temperature to rise considerably.
The warm refrigerant is led to the condenser. Here, the refri-
gerant gives off its energy to the hot water, whereupon the
refrigerant changes state from gas to liquid.
The refrigerant then goes via filters to the expansion valve,
where the pressure and temperature are reduced.
The refrigerant has now completed its circulation and re-
turns to the evaporator.
XL 4
XL3
Cold water connection
XL4
Hot water connection
Caution
This is a principle of operation. For more detailed
information about F110, see section "The Heat
pump design".
14
Chapter 4 | Pipe and air connections
3
Dimensions and pipe
connections
XL48
XL3
XL4
SETTING OUT DIMENSIONS
Connection
XL3 Cold water
XL4 Hot water
XL48 Safety valve
WM1 Overflow cup
PIPE DIMENSIONS
Connection
XL3 Cold water ext Ø
XL4 Hot water ext Ø
XL48 Safety valve ext. Ø
WM2 Overflow water discharge
WM2
WM1
C
A
A
B
(mm)
125
295
(mm)
125
350
(mm)
123
295
(mm)
140
450
(mm)
(mm)
(mm)
(mm)
NIBE F110
B
C
435
435
470
68
22
22
15
32