Nibe F110 User Manual

Nibe F110 User Manual

Hot water heat pump
Hide thumbs Also See for F110:

Advertisement

Quick Links

Библиотека СОК 
User manual
NIBE™ F110
Hot water heat pump
UHB GB 1434-1
231975

Advertisement

Table of Contents
loading

Summary of Contents for Nibe F110

  • Page 1 Библиотека СОК  User manual NIBE™ F110 Hot water heat pump UHB GB 1434-1 231975...
  • Page 2 A detailed explanation of the button functions can be found on page How to scroll through menus and make different settings is described on page 14. To temporarily increase the amount of hot water, first press the down button to mark menu 2 (water droplet) and then press the OK button twice.
  • Page 3: Table Of Contents

    F110 – An excellent choice 2 The heating installation – the heart of the house Heat pump function Contact with F110 Maintenance of F110 3 F110 – at your service Set the ventilation Set the hot water capacity Get information Adjust the heat pump...
  • Page 4: Important Information

    Fan (fan speed, normal mode) Exhaust air fan in- stallation Serial number must always be given Certification that the installation is carried out according to instructions in NIBE's installer manual and applicable regulations. Date __________________ Signed _________________________ Chapter 1 | Important information NIBE™...
  • Page 5: Safety Information

    Rights to make any design or technical modifications are reserved. ©NIBE 2014. NOTE If the supply cable is damaged, only NIBE, its service representative or similar authorised person may re- place it to prevent any danger and damage. Symbols NOTE This symbol indicates danger to machine or person.
  • Page 6: Serial Number

    Marking F110 is CE marked and fulfils IP21. The CE marking means that NIBE ensures that the product meets all regu- lations that are placed on it based on relevant EU directives. The CE mark is obligatory for most products sold in the EU, regardless where they are made.
  • Page 7: Contact Information

    Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: info@nibe.fi www.nibe.fi NIBE Energy Systems France Sarl, Zone industrielle RD 28, 01600 Reyrieux Tel : 03 88 06 24 10 Fax : 03 88 06 24 11 E-mail: info@nibe.fr www.nibe.fr NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk...
  • Page 8 NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: info@nibe.se www.nibe.se For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information. Chapter 1 | Important information...
  • Page 9: F110 - An Excellent Choice

    F110 – An excellent choice F110 is part of a new generation of heat pumps, which have been intro- duced to supply your home with inexpensive and environmentally friendly hot water. Hot water production is safe and economical with integrated water heater, immersion heater and control system.
  • Page 10: The Heating Installation - The Heart Of The House

    Expansionsventil Kompressor Förångare 0 °C 5 °C 0 °C 22 °C The temperatures are only examples and may vary between different installations and time of year. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 11: Heat Pump Function

    The temperatures are only examples and may vary between different installations and time of year. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 12: Contact With F110

    Contact with F110 Display unit There is a display unit on F110, which is used to communicate with F110. Here you: set the hot water and ventilation, if any, as well as adjust the heat pump to your needs. receive information about settings, status and events.
  • Page 13 With the up and down buttons you can: scroll in menus and between options. increase and decrease the values. Menu system When F110 is started you come to the information menu. Basic information about the heat pump status is shown here. The information menu shows: on starting.
  • Page 14 This symbol is displayed when the compressor is operating. This symbol is displayed when the additional heat is operating. This symbol appears when the speed of the fan is changed from its normal setting. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 15 This symbol appears if lux mode for the hot water is activated. This symbol appears when "scheduling" is activated in menu 2.3. This symbol appears when "holiday setting" is activated in menu 4.7. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 16 Mark the applicable option using the up or down button. One of the options is pre-selected (white). Press the OK button to confirm the selected option. The selected option has a green tick. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 17 Press the OK button to confirm the value you have set. To undo and return to the original value, press the back button. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 18 1. Mark, using the up and down keys, one of the arrows in the top left corner (at the page number). 2. Press the OK button to scroll between the windows in the start guide. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 19: Maintenance Of F110

    Maintenance of F110 Regular checks Your heat pump requires minimal maintenance after commissioning. On the other hand, it is recommended that you check your installation regu- larly. If something unusual occurs, messages about the malfunction appear in the display in the form of different alarm texts. See alarm management on page 32.
  • Page 20 Clean the F110's air filter regularly, how often depends on the amount of dust in the ventilation air. 1. Switch off the fan in F110 by holding the standby button for 3 seconds. (Display turns off.) 2. Pull out the filter cassette.
  • Page 21 4. Ensure air supply by opening all hot water taps. Caution The heat pump is started when the supply cable is connected to an earthed socket. Chapter 2 | The heating installation – the heart of the house NIBE™ F110...
  • Page 22: F110 - At Your Service

    3 F110 – at your service Set the ventilation ventilation Menu 1 This menu is only shown with ex- haust air installation. Setting range: normal and speed Default value: normal The ventilation in the accommodation can be temporarily increased or reduced here.
  • Page 23: Set The Hot Water Capacity

    Default value: "off" When hot water requirement has temporarily increased this menu can be used to select an increase in the hot water temperature to lux mode for a selectable time. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 24 The function is activated immediately when a time period is selected and confirmed using the OK button. The remaining time for the selected setting is shown to the right. When the time has run out F110 returns to the mode set in menu 2.2. Select “off" to switch off temporary lux...
  • Page 25 Scheduling always starts on the date that the start time is set for. If time periods overlap each other at midnight, the time period that starts after midnight is prioritised. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 26 The length of time between increases can be selected here. The time can be set between 1 and 90 days. Factory setting is 14 days. Untick "activated" to switch off the function. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 27: Get Information

    Push the up and down buttons to scroll between the pages. Symbols in this menu: Compressor Addition Ventilation (only shown Lux mode for hot water with exhaust air installa- tion) Scheduling Holiday setting Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 28 No changes can be made. add. heat info Menu Information about the additional heat’s operating status and statistics can be obtained here. No changes can be made. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 29 Menu To view the run status in the event of an alarm, mark the alarm and press the OK button. Information about an alarm. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 30: Adjust The Heat Pump

    "add. heat only", but only when additional heat is used. Change the operating mode by marking the desired mode and pressing the OK button. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 31 & date Menu Set time and date and display mode here. language Menu Choose the language that you want the information to be displayed in here. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 32 This menu is only available if an alarm alarm 291 has occurred. charge pump Here you can reset any alarms that have oc- curred in F110. aid mode reset alarm Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 33 Menu All settings that are available to the 4.9.4 user (including advanced menus) can be reset to default values here. Caution After factory settings, user settings must be reset. Chapter 3 | F110 – at your service NIBE™ F110...
  • Page 34: Disturbances In Comfort

    Alarm In the event of an alarm a malfunction has occurred that F110 cannot rectify itself. The display shows what type of alarm it is and lets you reset the alarm. You can also choose to set the heat pump to rescue mode reset alarm In most cases it is enough to select "reset alarm"...
  • Page 35 The sensor has lost contact with the accessory card or is broken. The alarm resets automatically after correct connection. Contact your installer! Communication alarm display The display has lost contact with the base card. Contact your installer! Chapter 4 | Disturbances in comfort NIBE™ F110...
  • Page 36: Troubleshooting

    Basic actions Start by checking the following possible fault sources: That the display is lit or that the supply cable to F110 is connected. Group and main fuses of the accommodation. The property's earth circuit breaker.
  • Page 37 Clean or replace filter (see page 18). Gurgling sound Not enough water in the water seal. Refill the water seal with water. Choked water seal. Check and adjust the condensation water hose. Chapter 4 | Disturbances in comfort NIBE™ F110...
  • Page 38: Technical Data

    5 Technical data Detailed technical specifications for this product can be found in the in- stallation manual (www.nibe.eu). Chapter 5 | Technical data NIBE™ F110...
  • Page 39: Glossary

    Compresses the gas state refrigerant. When the refrigerant is compressed, the pressure and the temperature increase. Condenser Heat exchanger where the hot gas state refrigerant condenses (cools and becomes a liquid) and heats the hot water. Chapter 6 | Glossary NIBE™ F110...
  • Page 40 Supply temperature The temperature of the heated water that the heat pump sends out to the heating system. The colder the outdoor temperature, the higher the supply line temperature becomes. Chapter 6 | Glossary NIBE™ F110...
  • Page 41: Index

    Item register Adjust the heat pump, 28 Important information, 2 Contact information, 5 Contact information, 5 F110 – An excellent choice, 7 Contact with F110, 10 Installation data, 2 Menu system, 11 Serial number, 4 Room unit, 10 Installation data, 2...
  • Page 44 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 231975...

Table of Contents