Setting the Eco mode temperature self lowering
The drop in temperature is set at -3.5°C compared to the set temperature of the Comfort mode. You can adjust the lowered level from -1°C to -8°C, by
intervals of 0.5°C.
Important: whatever the lowering level set, the Eco set temperature will never exceed 19°C.
By pressing the Mode button,
1
several times, position the
arrow beside the Eco mode.
Setting the Frost protection temperature
Your radiator is preset at 7°C. You can adjust the Frost protection temperature from 5°C to 15°C, by intevals of 0.5°C.
By pressing the Mode button,
several times, to position
1
the arrow beneath the Frost
protection mode.
Overview
Dual function optimisation, priority to comfort or energy savings, the choice is yours: Depending on various parameters: room inertia, ambient tem-
perature, desired temperature, the radiator calculates and optimises the programming for each heating period whether set to Comfort or Savings (Eco):
- In OPTI ECO mode (efficiency priority), the radiator inbuilt algorythmes will calculate the best compromise in order to guarantee maximum energy
savings throughout the programmed increase and decrease phases.
In this mode, a slight drop in the temperature level at the beginning and end of the comfort period is allowed to maximise energy savings.
- In OPTI COMFORT mode (priority to comfort), the radiator intelligence calculates the best compromise in order to guarantee maximum comfort
during the programmed increase and decrease phases.
In OPTI COMFORT mode, the priority is given to anticipating and maintaining the comfort temperature during periods of detected occupancy.
8 sec.
Press Mode and Plus simul-
2
taneously for 8 seconds to
enter in the setting mode.
8 sec.
Press Mode and Plus buttons
2
simultaneously for 8 seconds
to enter in the setting mode.
D
UAL OPTIMISATION FEATURE
Press Minus or Plus to obtain
3
the temperature level you
require.
Press Minus or Plus to obtain
3
the temperature you require.
21
Save by pressing Mode.