Connected electric radiator with mineral oil with 7 day programme,
open window detection, gauge and energy consumption indication
and PIN code lock
Smart features:
Occupancy detection - Automatic programming with self-
learning process and dual optimisation feature
INSTALLATION AND
OPERATING INSTRUCTIONS
Can be remotely-controlled
by the free application
FR9011480-90-500B-03-22

Advertisement

Table of Contents
loading

Summary of Contents for Supra Dalbeo WiControl 1022

  • Page 1 Dalbeo Wi-Control Dalbeo Wi-Control Connected electric radiator with mineral oil with 7 day programme, open window detection, gauge and energy consumption indication and PIN code lock Smart features: Occupancy detection - Automatic programming with self- learning process and dual optimisation feature INSTALLATION AND OPERATING INSTRUCTIONS Can be remotely-controlled...
  • Page 2: Table Of Contents

    Table of contents Table of contents • Installing the heating device ..........................3 • Warnings and precautions ............................................3 • Connecting, wall-mounting procedure .......................................5 • Overview ................................7 • Benefits ....................................................7 • Diagram ...................................................8 • Operating ................................9 • Power on / Heating standby mode ........................................9 •...
  • Page 3: Installing The Heating Device

    Installing the heating device Installing the heating device ARNINGS AND PRECAUTIONS Warnings All damage resulting from non-compliance with sensory or mental capabilities or lack of experience this advice gives rise to non-application of the and knowledge, if they have been given supervi- terms of the manufacturer’s warranty.
  • Page 4 Suggestion, positioning, location Before connecting up the radiator to the mains shower cabinet (in accordance with I.E.E. Wiring Reg- power supply, switch off mains power at the main ulations (BS 7671:2008)). circuit breaker. The radiator must not be located immediately below This electric radiator is a class II double insulated IP24 a socket-outlet.
  • Page 5: Connecting Wall Mounting Procedure

    ONNECTING WALL MOUNTING PROCEDURE Connecting the device All electrical installation work should be carried - The three wires must be connected in an electrical out by a suitably qualified Electrician or other connection fuse spur box which complies with ap- competent person.
  • Page 6 Setting up of the radiator on the wall-mounting brackets 1- Take the radiator by the sides and lift it slightly by 2- Place the radiator on the wall-mounting brackets. presenting it parallel to the wall. Top view Side view Top view Side view At the back of the product, make sure that each wall-mounting brackets are inserted between the intermedi- ate fins without altering them.
  • Page 7: Overview

    Our range of electric radiators with thermal fluid with innovative style was designed and developed to bring you the com- fort of heating without maintenance and significant energy savings thanks to the new smart features: your SUPRA radiator incorporates innovative technologies designed for your comfort and to increase your energy saving, control performance PID (stability), occupancy detection, open window detection, 7 day and daily programme, optimisation feature.
  • Page 8: Diagram

    - Administrator/installer PIN code. - Overheating protection: The radiators are equipped with a system pro- tecting the device against any overheating. - Boost (available through the application mySUPRA): Rises the heat of the room for an adjustable time and in a punctual manner. - No risk of the radiator falling on the wall: Secure patented wall brack- ets fixing system.
  • Page 9: Operating

    Operating Operating OWER ON EATING STANDBY Your device is in connection mode. Please refer to the instructions MODE on your application mySUPRA and follow the instructions until the complete connection of the device. Note: During your pairing procedure, the following 3 screens will appear on the radiator.
  • Page 10: Manual And Temporary Exemption Override To A Current Operating Mode

    Mode description Display Mode description Display 2 different cases depending on your set-up: Boost duration The Boost is active for a preset and adjustable 7 day and daily programme time of 60 min. Your radiator has been programmed and is executing Comfort and Eco On your device and through the application mode orders in line with the settings and time periods you have selected mySUPRA, you have the possibility to change...
  • Page 11: Adjustment Of Setting Temperatures

    So, depending on the set temperature, you can choose your level of energy Comfort+ temperature usage. As the temperature setting increases, the consumption will be higher. The gauge appears in Auto, Comfort, Eco and Frost protection modes re- gardless of the level of temperature. Adjustable from Comfort +1°C to 30°C by intervals Preset at...
  • Page 12: Consumption Indication Accumulated In Kwh, Energy Savings

    ONSUMPTION INDICATION HILD ANTI TAMPER ACCUMULATED IN KWH ENERGY KEYPAD LOCK UNLOCK SAVINGS It is possible to see the estimation of power consumption in kWh since the • Keypad lock last reset of the energy meter. From the Auto, Comfort, Comfort+, •...
  • Page 13: Day And Daily Programme Integrated Energy Savings

    is not interrupted by an external source, see important information concerning the presence detection system on page 15. The minutes are flashing, set by pressing Minus or Plus. Confirm by pressing OK. Example of display in Eco period The dash below the number •...
  • Page 14 1 Comfort period per day Selection of day(s) 2 Comfort periods per day (Self-learning) corre- 3 Comfort periods per day sponding to the auto-pro- gramming appears on the Non-stop Comfort display. Non-stop Eco Press Minus or Plus to select Non-stop Frost protection the day or group of days you wish to program.
  • Page 15: Dual Optimisation Feature

    If the device is located close to a front door, the detection may be dis- • Visualization of the assigned programmes turbed by the air caused by opening door. If this is a problem, we recommend that you disable the automatic mode opened window detection (see page 19).
  • Page 16: Information About Remote Control By Pilot Wire

    Side view - Objects moving with the wind like curtains and plants. Disable the occupancy detection if your radiator was installed near of these. To disable the occupancy detection, see page 20. Note: the detection range varies depending on the ambient temperature. •...
  • Page 17: Information About Priorities Between The Different Modes

    User settings User settings NFORMATION ABOUT PRIORITIES BETWEEN THE DIFFERENT MODES • Accès Press several times on M until the • Principle cursor is under (User set- In Comfort, Eco and Frost protection mode, only orders of the occupan- tings) appears on the display. Press cy sensor and those of the opened window sensor will be considered.
  • Page 18: Holidays Mode

    OLIDAYS MODE ISCONNECTION IF THE PRODUCT IS CONNECTED TO NTERNET You can program an absence period during which your installation will be protected from frost. At the end of this period, the device will return to In case: Auto mode. This guarantees you maximum savings during your holidays - If you want to disconnect the product from the Wi-Fi®...
  • Page 19: Advanced Settings (Installer Or Advanced Users)

    Advanced settings Advanced settings (installer or advanced users) (installer or advanced users) • Access Press several times on M until the cursor is under (User Select and press 5 sec- settings) appears on the display. Press Minus or Plus until (In- onds on OK.
  • Page 20: Occupancy Detection: Activation/Deactivation

    To confirm and move to the next setting, press OK. To exit experts • High temperature limitation settings, press M for 3 seconds. A maximum limit stop is installed to prevent the set temperature from being increased above it. Note: Even if the automatic mode is deactivated, you can still use the The maximum limit is preset at 30°C.
  • Page 21: Dual Optimisation Feature

    UAL OPTIMISATION FEATURE • PIN code initialisation • Optimisation choice By default, the PIN code is not enabled. The OPTI COMFORT mode is enabled by default. The inscription appears briefly on the display and then displayed. The inscription appears briefly on the display. Press Minus or Plus to select the desired mode.
  • Page 22: Connection Disable (Airplane Mode)

    To confirm and move to the next setting, press OK. To exit experts appears again on the dis- settings, press M for 3 seconds. play. Press OK to activate the PIN Note: If airplane mode is on and you wish to reconnect by following the code you have just personal- instructions on page...
  • Page 23: Experts Settings (Reserved To The Installer)

    DJUSTING THE BRIGHTNESS OF THE REDUCED DISPLAY Settings Factory settings Installer settings Automatic open window detection Enabled The brightness of the reduced display is 50% by default Occupancy detection Enabled Minimum setting of Comfort set 7°C temperature Maximum setting of Comfort set 30°C temperature Press Minus or Plus to adjust...
  • Page 24: Choice Of Power

    ELETING LOGIN INFORMATION To permanently delete the Wi-Fi® connection information from the product, follow the steps below. Decrease the temperature measured by the ambient temperature sensor by 2°C by pressing Minus. In our example the measured apppears briefly on the temperature by the sensor goes screen.
  • Page 25: Load Shedding And Power Cut

    This allows you to reduce the energy power subscribed and therefore opti- mize your subscription with your energy provider. 5 sec. SUPRA heating devices are designed to operate with load shedding sys- The following factory values will be effective: tems with pilot wire only.
  • Page 26: Troubleshooting

    Troubleshooting Troubleshooting IAGNOSIS SUPPORT • Connection to Wi-Fi® The ambient temperature measured by a thermometer doesn’t corre- spond to the set temperature after several hours. When the device’s connection to your Wi-Fi® network has encountered an - An offset is always possible, you can refine the device setting (see page anomaly: blink.
  • Page 27: Technical Information

    - If the padlock symbol is displayed, the keypad lock is enabled.Unlock the Error message Description What to do? keypad as shown in the manual, child anti-tamper section (see page 12). Turn off the power to the - Check the lock PIN code and the Comfort setpoint temperature limitation Anomaly on the product for 5 seconds by (see page 20 and 21).
  • Page 28: Technical Specifications

    ECHNICAL SPECIFICATIONS General specifications: Environment: - Power supply: 230V +10/-14 % AC 50Hz. - Safety: Classe II, IP24. - Maximum RF power transmitted: <20dbm. - Storage temperature: -20°C to +70°C. - Consumption in heating standby mode: <1W. Features: - Proportional Integral Derivative control, with engagement by triac. - Setpoint adjustment range Confort +7°C to +30°C.
  • Page 29: Information Requirements For Electric Local Space Heaters