CHAPTER 7 ELECTRICAL
5. Thermo switch
Remove the thermo switch from the
radiator.
Connect the pocket tester (ΩX1) to
the thermo switch.
Immerse the thermo switch in the
water 
Check the thermo switch for
continuity.
NOTE:
Measure
temperatures
heating
the
coolant
temperature gauge
WARNING
Handle the thermo switch with
special care.
Never subject it to strong shocks or
allow it to be dropped. Should it be
dropped, it must be replaced.
Do not touch the thermo switch to
the bottom of the heated vessel.
88± 3℃Thermo switch "ON"
80± 3 ℃Thermo switch "OFF"
6.Relay
Disconnect the starting circuit
cut-off
relay
coupler
wireharness.
Connect the pocket tester (Ωx1)
and battery (12V) to the starting
circuit cut-off relay coupler terminals.
Battery (+) lead→ terminal 
Battery (-) lead→ terminal 
Check the starting circuit cut-off
relay for continuity.
Test (+) lead →  terminal
Test (-) lead →  terminal
while
with
the
from
the
T-Boss550 SERVICE MANUAL 20.0
OUT OF SPECIFICATION
Replace the thermo switch
CHAPTER 7 ELECTRICAL CTRICAL PAGE 7- 18