CHAPTER 7 ELECTRICAL
7.6 COOLING SYSTEM
IF THE FAN MOTOR FAILS TO TURN
Procedure
Check:
1. Fuse (Main, Fan)
2. Battery
3. Main switch
1.Fuse
CHECK SWITCHES
2. Battery
T-Boss550 SERVICE MANUAL 20.0
4. Fan motor (inspection)
5. Thermo switch
6. Relay
7.Wiring
connection
system)
NO CONTINUITY
Replace the fuse
CHAPTER 7 ELECTRICAL CTRICAL PAGE 7- 16