Cross flow fans with direct current drive (8 pages)
Summary of Contents for ZIEHL-ABEGG ECblue BASIC-MODBUS
Page 1
ECblue BASIC-MODBUS, ECblue BASIC Motor sizes: D (116), G (152) EC-fans and motors with highest efciency Quick Start Guide Keep for reference! Detailed Assembly instructions on www.ziehl-abegg.com L-BAL-F078-GB 2024 Index 005 Part.-No. 00706648-GB...
We do not accept any liability for possible errors or omissions in the information contained in data, illustrations or drawings provided. ZIEHL-ABEGG SE is not liable for damage due to misuse, improper use or as a consequence of unauthorized repairs or modifications.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Safety instructions 2 Safety instructions This chapter contains instructions to prevent personal injury and property damage. These instructions do not lay claim to completeness. In case of questions and problems, please consult our company technicians.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Safety instructions Attention, automatic restart! • The fan / motor may switch on and off automatically for functional reasons. • After power failure or mains disconnection an automatic restart of the fan takes place after voltage return! •...
The fans may not be operated until they are installed in line with their intended use. The supplied and certified guard grille of ZIEHL-ABEGG SE fans is designed in accordance with DIN EN ISO 13857 Table 4 (from the age of 14 up). In the event of deviations, further structural protective measures must be taken for safe operation.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Mounting • Store the fan / motor in the original packaging in a dry area protected from the weather and protect it from dirt and weather until final installation. • Avoid prolonged storage; we recommend a maximum of one year (consult the manufacturer before starting if stored for longer).
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Mounting – If the mounting height (danger area) above the reference plane is greater than or equal to 2700 mm and is not reduced by auxiliary means such as chairs, ladders, working platforms or floor space on vehicles, a guard grille is not necessary on the fan.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Mounting 4.2.3 Assembly of MAXvent fans type FV, DN, For attachment to fixed motor flange use screws with property class 8.8 or A2-70 (stainless steel) to EN ISO 4014 and provide with suitable screw locking.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation • Motors are not balanced as standard, a complete balancing with mounted fan impeller is necessary. The balancing must be done on the fan impeller. The pertinent regulations must be observed.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation Version without connection cables ECblue BASIC connection version example 1 Cover of controller housing 2 Motor size “G”: Cable glands 3 x M20 inserted: 1 x Black seal insert for cables with 8...12 mm outer diameter inserted: 2 x Blue seal insert for cables with 6...7.9 mm outer diameter...
Page 12
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation • Remants from installation and foreign object may not remain on the inside! Remants from installation, foreign objects and dirt has to be removed from the sealing area between cover and controller housing!
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation 5.2.1 Assembly notes for cable glands Correct use of the cable glands is of crucial importance for high operational reliability; note the following instructions. Construction of a cable gland 1. O-ring 2.
Page 14
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation Cables and installation position " Depending on the installation position and load, run the connecting cables to the cable gland from below or fit a water draining pipe elbow. Note Do not use any additional cable sheathing (e.g. with insulating tape or "...
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation Connection versions Each version can be supplied with an integrated AM-STICK-WB Bluetooth communication module, and this option is indicated by the addition of “WB” to the type designation (see rating plate), e.g.
Page 16
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Electrical installation ECblue BASIC-MODBUS (_ _ _ _ _-_I_.D_._ _ _ _), (_ _ _ _ _-_I_.G_._ _ _ _) Kontaktbelastung Contact rating max. AC 250 V 2 A PORT 1 PORT 2...
3. If resonance vibrations occur, it is possible to hide certain speed ranges (see Motor Setup). 4. Fans from ZIEHL-ABEGG SE are delivered balanced in accordance with DIN ISO 21940-11 for the appropriate fan category in accordance with ISO 14694 Check the fan for mechanical vibrations after installation.
• Customers who sell or use these ZIEHL-ABEGG products for these applications do so at their own risk. They undertake to reimburse ZIEHL-ABEGG in full for any possible costs that may occur. •...
50 %. Label Datamatrix-Code serial number Every ZIEHL-ABEGG product (fan/inverter), supplied with a built-in AM-STICK-WB or with a slot for it, comes with an additional sticker for addressing via Bluetooth®. This sticker is individualized for the final product. On the sticker is the serial number, which is unique to each product and matches the serial number on the product rating plate.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC AM-STICK-WB Establishing the Bluetooth connection Proceed as follows: 1. Depending on your device, download and install the "ZAset Mobile" app from Google Play Store or Apple App Store. 2. Start the app and, if necessary, open the Settings area with the gear wheel symbol.
Page 22
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC AM-STICK-WB 5. Tap the "Bluetooth" button to create a system with a Bluetooth LE data connection. ZAset checks whether Bluetooth is activated on your smartphone, and prompts you to activate it if necessary.
Page 23
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC AM-STICK-WB 8. As soon as a connection to the device is established, a two-stage authentication process is initiated. – First stage: Binding (linking AM-STICK-WB with device serial number). The app checks whether the MAC address of the stick has already been assigned a serial number.
Page 24
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC AM-STICK-WB – Set a new PIN to prevent unauthorised access. 9. If required, enter a name of your choice (alias) Example: 01_ECblue L-BAL-F078-GB 2024 Index 005 Part.-No. 00706648-GB 24/32...
Page 25
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC AM-STICK-WB 10. Press the button on the device to establish the connection (the colour of the Bluetooth symbol changes from red to green). 11. Actual values on Dashboard when connection is established successfully.
Page 26
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC AM-STICK-WB 12. Buttons for subsequent operation can be found on the dashboard. 1 Menu: Start, List my devices, Settings 2 Disconnecting the Bluetooth connection 3 Info: BLE vesion, MODBUS address, identification etc. 4 Error history...
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Diagnostics / Faults 8 Diagnostics / Faults Status output with flashing code Vision panel for status LED in the case of plastic cover design 22.06.2012 v_flash_expl_red_1_x.VSD LED Code Relays K1* Cause Explanation No voltage supply.
Page 29
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Enclosure Ball-bearings service life The according to standard calculation methods determined bearing service life expect- ation of the motor-integrated ball bearings is mainly determined by the grease service life F10h and amounts for standard application to approx. 30.000 - 40.000 operating hours.
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Enclosure EC Declaration of Incorporation - Translation - (english) ZA87-GB 1836 Index 008 as defined by the EC Machinery Directive 2006/42/EC, Annex II B The design of the incomplete machine: Axial fan FA.., FB.., FC.., FE.., FF.., FG.., FS.., FT.., FH.., FL.., FN.., FV.., DN.., VR.., VN.., ZC.., ZF.., ZG.., ZN..Centrifugal fan RA.., RD.., RE.., RF.., RG.., RH.., RK.., RM.., RR.., RZ.., GR.., ER..,...
Page 31
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Enclosure It is prohibited to commission this incomplete machine until it has been secured that the machine into which it was incorporated complies with the stipulations of the EC Machinery Directive. Künzelsau, 03.09.2018...
Quick Start Guide ECblue BASIC-MODBUS, ECblue BASIC Enclosure Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: ZIEHL-ABEGG SE Heinz-Ziehl-Straße...