Program Sounder

The following system options are programmed in this section:
Option
Burglary Alarm Sound
Burglary Bell Timeout
Fire Bell Timeout
Arm Confirm
Alarm Options

Program System Settings

The following system options are programmed in this section:
Option
Entry Delay1/Entry Delay 2
Exit Delay
Backlight Timeout
Quick Arm
Quick Exit
Restart Exit Time
Force Bypass
Exit Warning
Auto Stay Arming
Lack of Usage Notify
Power-Up in Previous
Display Alarm Cancel
Display Exit Time
Cross Zone Delay
Cross Zone 1/Cross Zone 2
Reduces the full 85 dB burglary alarm sound for testing.
Select the time for timeout of the Burglary Alarm sounder.
Select the time for timeout of the Fire Alarm sounder.
Enable sounder "ding" when system is armed via the selected RF device.
Select a limit for the number of times an alarm can sound for a specific zone.
Note: This option does not apply to the L5210/L7000 controls.
Selects an Entry Delay time in seconds. The system will wait the time entered before
sounding alarm upon entering if system is not disarmed.
Selects an Exit Delay time in seconds for both Entry Delay 1 and 2 Zone Types. The
system will wait the time entered before sounding an alarm if the exit door is left open after
the system has been armed.
Enable or disable display backlight turnoff after 30 seconds.
Enables or disables Quick Arm Mode. If enabled, security code is not required to arm the
system. The user simply presses the AWAY button (ICON) and then selects the "Quick
Arm" button on the displayed keypad to arm the system.
Enables or disables Quick Exit Mode. If enabled allows the user restart the exit delay to
allow entry or exit when the system is armed
Enables or disables Restart Exit Time Mode. This option allows the control to restart the
exit delay time (one time) after arming in STAY or AWAY mode by selecting the Restart
key (if quick arming is enabled) or by selecting the Restart key and entering the User Code
(if quick arming is disabled). This option also enables automatic exit delay reset, which
resets exit delay if the entry/exit door is re-opened and closed before exit delay time
expires after arming.
Enables or disables Force Bypass Mode. All zones bypassed by this function will be
displayed after the bypass is initiated. The Fire and CO Zones are not bypassed in the
L5210/L7000.
Enables or disables Exit Warning sound. Audible Exit Warning sound consists of slow
continuous beeps until last 10 seconds, when it changes to fast beeps. The warning sound
will end at the termination of exit delay.
Note: This field is not programmable in the L5210/L7000 and is always enabled.
Enables or disables Auto Stay Arming Mode. If this feature is enabled and the Control
Panel has been armed "Armed Away" at the LYNX Touch keypad or RF keypad, the
system will switch to the "Armed Stay" mode if the Exit Time has expired and no exit has
been made.
Enables or disables Lack of Usage Notification feature. If enabled, notifies the Central
Station if an end user is not operating their security system by sending a System Inactivity
report 654. The report will be sent only to the Primary phone number and only if Contact
ID® format was selected.
Enables or disables Power-Up in Previous Mode feature. When the system powers up
armed, an alarm will occur 1 minute after arming if a zone is faulted. For the
L5210CN/L7000CN control any bypassed zones will be unbypassed. For the L5210/L7000
any bypassed zones will remain bypassed.
Enables or disables display of Cancelled Alarm.
Enables or disables display of Exit Time.
Sets the maximum amount of time in which two zones must be tripped in an armed system
to send an alarm message to the Central Station. If only one cross zone is tripped during
this time, a trouble message (CID code 380) for that zone is sent to the Central Station.
Select the zones that will be used for Cross Zoning
- 31 -
LYNX Touch Installation and Setup Guide
Programming the Control