Cdma Information; Communications Id Numbers; Test Communications - Honeywell L5210 Series Installation And Startup Manual

Hide thumbs Also See for L5210 Series:
Table of Contents

Advertisement

CDMA Information – Displays CDMA information associated with the installed/enabled and registered
CDMA-L57 Communications Module.
Status
CDMA Registered
CDMA Not Registered
Searching For Coverage!
Cell Registration: Deactivated
RSSI Note: Primary Site Signal strength is displayed by a series of 1 to 5 stars (* weak to ***** strong) or "Not Present" if there is no signal.
To ensure a reliable installation at least 2 (**) stars should consistently be present.

Communications ID Numbers

Message
MAC:
xxxxxxxxxxxx
MAC CRC:
xxxx
WiFi:*
xxxxxxxxxxxx
WiFi Ver:
x.x.x
SCID:**
xxxxxxxxxxxxxxxxxxxx
IMEI:**
xxxxxxxxxxxxxxx
ESN:***
xxxxxxxx
* This is the system MAC that should be referenced whenever speaking with technical support.
** Displayed if GSM communication path is enabled.
*** Displayed if CDMA communication path is enabled.
Test Communications – Performs network diagnostics and sends test alarms to AlarmNet. The following
tests are available depending on the type of communications module installed.
Test Ethernet
This test is available if IP communication path is enabled. The network diagnostic process tests the integrity of the links
between the LYNX Touch and the various connection points of AlarmNet Control that are known as "Redirectors". If a physical
link is detected and is ready, the following diagnostics are performed.
Testing Gateway...Traces the connection to the Gateway and displays the following:
Testing Gateway – Successful!
Testing Gateway – Failed!
Testing Redirector * Sequentially traces the connection to Redirector 1, 2 and 3 at AlarmNet Control and displays:
Redirector * – Service OK
Redirector * – Failed
* = Number of the director being tested is displayed
A summary of the tests is displayed after Redirector 3 is tested. The example shows that the tests of all three
connection points, or Redirectors, were successful. If an error occurred at any point, the summary will display "Failed"
next to the faulty Redirector.
Redirector 1 – Service OK
Redirector 2 – Service OK
Redirector 3 – Service OK
If no physical link is detected, the test is aborted and one of the following is displayed:
No Physical Link
Link Not Ready
Send Any
If both IP and Cellular communication paths are enabled and the LYNX Touch is registered, a Test alarm is sent over IP path.
If that is not successful, it sends the alarm over the Cellular path and the following message is displayed: Test Message Sent
If the device is not registered, the following is displayed: Test Message Failed – Not Registered
Send Cellular Message
If Cellular communication path is enabled, and the LYNX Touch is registered, a Test alarm is sent to AlarmNet over the
Cellular path only . The following message is displayed: Test Message Sent
If the device is not registered, the following message is displayed: Test Message Failed – Not Registered
Message
Cell Registration:
Home CDMA
Roaming
(See RSSI
Primary RSSI:
Note below)
SID:
xxx
NID:
xxx
Channel:
xxx
Ec/lo:
xxx
MAC Address indicates the unique identification number for installed
communications module(s)
MAC CRC number for installed communications module(s)
Physical MAC Address of the WiFi module
WiFi module software version
Displays the ID number assigned to the installed SIM card (SCID)
Displays the ID number assigned to the installed GSM module.
Displays the ID number assigned to the installed CDMA module.
A successful trace to Gateway. OR
Failed to reach Gateway.
Service at AlarmNet Control on Redirector 1, 2 or 3 is functioning. OR
Error occurred on Redirector 1, 2 or 3.
No physical link is detected.
There is a link but it is not ready (address not resolved).
LYNX Touch Installation and Setup Guide
Programming the Control
Registered Home with CDMA 1x Service
Registered Roaming
Primary Site RSSI level signal strength
(1 to 5 stars or "Not Present" will be displayed)
System ID
Network Code
Channel in use
Ratio of received signal power to overall noise
Searching for cell network.
Not registered with cell network
Meaning
- 33 -
Meaning