Load Shedding And Power Cut; Load Shedding By Pilot Wire Only; Other Remotely Management By Power Shutdown; In Case Of Power Cut, Backup - Supra Dalbeo WiControl 1022 Installation And Operating Instructions Manual

Connected electric radiator with mineral oil with 7 day programme, open window detection, gauge and energy consumption indication and pin code lock
Table of Contents

Advertisement

Select
and press OK for 5
3
seconds.
The following factory values will be effective:
Settings
User settings
Comfort setting temperature
Comfort+ setting temperature
Eco setting temperature
Frost protection setting tempera-
ture
Active operating mode
Active operative mode
Backlighting
Installer settings
Automatic open window detection
Occupancy detection
Minimum setting of Comfort set
temperature
Maximum setting of Comfort set
temperature
Aeration cycle time
Dual optimisation feature
Value of the PIN code
Wi-Fi® connection
Expert settings
Reduced display brightness
Ambient temperature sensor ad-
justment
The radiator returns to its original
configuration and automatically
returns to the expert settings
home display.
5 sec.
Factory settings
19°C
21°C
15,5°C
7°C
Auto
Appr (auto-programmation)
L2
Enabled
Enabled
7°C
30°C
30 minutes
Comfort
0000
Enabled
50%
0.0
Load shedding and
Load shedding and
power cut
power cut
L
OAD SHEDDING BY PILOT WIRE ONLY
In case of over consumption, an energy power manager or a disconnector
doesn't trigger a trip of the general (example: simultaneous operating of
your various household appliances and others).
This allows you to reduce the energy power subscribed and therefore opti-
mize your subscription with your energy provider.
SUPRA heating devices are designed to operate with load shedding sys-
tems with pilot wire only.
Orders sent by the pilot wire are executed by the device's electronic con-
troller which will apply setpoint corresponding to the order sent.
The "Stop" order corresponds to the load shedding. When this order is
received, the device switches to "standby" and then returns to the initial
operating mode.
O
THER REMOTELY MANAGEMENT BY
POWER SHUTDOWN
Important : The power supply of the device should be
cut when working on the electrical system only. The load
shedding does not be operated by an additional system
with mechanized power shutdown (with contactor...).
Unlike pilot wire shedding, the load shedding with fre-
quent mechanized power shutdowns can cause deterio-
ration of the device depending of the quality of switching
elements used. This type of deterioration would not be
covered by the manufacturer's warranty.
If remotely stop or standby orders should be frequent-
ly operated, you must use the pilot wire (refer to previous "Load
shedding by pilot wire only" subsection).
I
N CASE OF POWER CUT
- The device will start up again without any outside input being required –
you do not have to do anything. All the settings and the correct time will
be saved.
When the main power supply returns, your device will again operate
using correct time and the settings that were programmed before the
power cut (as regards desired temperature, operating mode, programs,
etc.). It will start up again in the mode which was active before the power
outage.
- For longer power supply cuts (more than 3 days), check the timer set-
ting all the other settings are automatically and permanently saved.
25
,
BACKUP
FR9011480-90-500B-03-22