OVERHEATING SAFETY SYSTEM
- In the event of improper use (e.g. appliance covered while in operation), the overheating
safety system automatically switches off the appliance. If this system is triggered, the cause
of the overheating must be removed. The appliance automatically switches back on when the
temperature drops below the cut-out value.
TIP-OVER SAFETY SYSTEM
- If the radiator tips over during operation, the tip-over safety system switches it off automatically.
Stand the radiator back up and it will switch on again.
INSTALLATION
- Before switching the radiator on, make sure that all the precautions mentioned in the "safety
instructions" and the "minimum safety distances" sections are observed.
- This is a class I device and must be plugged into a power outlet.
- Stand the appliance on a rigid, stable surface (never on a thick carpet).
- Connect the appliance to the mains supply.
- When using the appliance for the first time, a slight odour may be detected for a few minutes due
to the materials heating up for the first time.
Warning:
- Do not use the radiator in bathrooms.

APPLIANCE OPERATION

- Connect the appliance to the mains supply.
- Set the switch (G) (fig. 2) to «I».
- Press button (6) (fig. 3) to switch on the appliance.
- When light (7) (fig. 3) switches off, this means that the appliance is operating.
- The LCD screen (1) (fig. 3) displays the room temperature.
- When light (8) (fig. 3) switches on, this means that the appliance is operating at minimum power.

POWER OPERATION

CORAIL 1503
CORAIL 2003
- Press button (4) or (5) (fig. 4) to select the power setting.
- Press (5) for minimum power (fig. 3). Indicator light (8) (fig. 3) lights up.
- Press (4) for maximum power (fig. 3). Indicator light (9) (fig. 3) lights up.

THERMOSTAT OPERATION

- Temperature range selection: 5°C to 36°C.
- Use buttons (4) and (5) (fig. 3) to select the desired temperature.
- The appliance will regulate and heat based on this temperature. Once set, the appliance remains
at the selected power setting.
TIMER
- Timer selection range: 0 to 18 hours in steps of 1 h.
- Press button (3) (fig. 3) to select timer mode.
Minimum power
750 W
1000 W
Maximum power
1500 W
2000 W