Experts Settings (Reserved To The Installer); Adjusting The Brightness Of The Reduced Display; Ambient Temperature Sensor Adjustment - Supra Dalbeo WiControl 1022 Installation And Operating Instructions Manual

Connected electric radiator with mineral oil with 7 day programme, open window detection, gauge and energy consumption indication and pin code lock
Table of Contents

Advertisement

Settings
Installer settings
Automatic open window detection
Occupancy detection
Minimum setting of Comfort set
temperature
Maximum setting of Comfort set
temperature
Aeration cycle time
Dual optimisation feature
Value of the PIN code
Wi-Fi® connection
The radiator returns to its original
configuration and automatically
returns to the installer settings
home display.
Experts settings
Experts settings
(reserved to the installer)
(reserved to the installer)
• Access
From the main screen, press several times M until the cursor is un-
1
der
.
(User settings) is displayed. Press Minus or Plus until
(Professional) appears on the display.
Press OK for 5 seconds to
2
access the Expert settings.
Schematic sequence of settings:

Adjusting the brightness of the reduced display

sensor adjustement
Choice of power
Reset experts settings
Factory settings
Enabled
Enabled
7°C
30°C
30 minutes
Comfort
0000
Enabled
5 sec.
Ambient temperature
Deleting login information
A
DJUSTING THE BRIGHTNESS OF THE
REDUCED DISPLAY
The brightness of the reduced display is 50% by default
Press Minus or Plus to adjust
1
the brightness of the reduced
display between 10% and
100% by intervals of 10%. The
change in brightness is visible
at each setting.
Press OK to confirm and move
2
to the next setting. To exit the
Expert settings, press M for 3
seconds.
A
MBIENT TEMPERATURE SENSOR
ADJUSTMENT
• Overview
Important: This operation is reserved for professional installers only;
any wrong changes would result in control anomalies.
In which case if the temperature measured (measured by a reliable ther-
mometer) is different by at least 1°C or 2°C compared to the set tempera-
ture of the radiator.
The calibration adjusts the temperature measured by the ambient temper-
ature sensor to compensate for a deviation from + 5°C to - 5°C by intervals
of 0.1°C.

• Ambient temperature sensor adjustment

1- If the room temperature difference is negative, example:
Set temperature (what you want) = 20°C.
Ambient temperature (what you read on a reliable thermometer) =
18°C.
Difference measured = -2°C.
Important: Before carrying out the calibration it is recommended to
wait for 4h after the set temperature modification to insure that the
ambient temperature is stabilized.
To correct, proceed as follows:
Sensor temperature = 24°C.
(The measured temperature may
be different due to the location of
the radiator in the room).
23
.
FR9011480-90-500B-03-22