ONNECTING
Connecting the device
All electrical installation work should be carried
out by a suitably qualified Electrician or other
competent person.
- The power supply of the device must have a means of
disconnection main supply capable of disconnecting
all poles, having a contact separation of at least 3mm
in accordance with local regulations and installation
rules, a protection by a 30mA differential switch and
a protection device against overloads adapted to the
characteristics of the connecting line.
- Before you first use the equipment, check that the
voltage used does indeed match that listed on the
device.
- This radiator is a class II device (meaning that it has
double electrical insulation). Connection to earth is
prohibited.
Positioning of the wall mounting bracket and
tracing
Fix the bracket according to the dimensions specified in the enclosed
table template, use the drilling template supplied.
Products
Dalbeo Wi-Control 1022
Dalbeo Wi-Control 1522
Dalbeo Wi-Control 2022
Stage 1
Open the template and position
it against the wall, at the desired
location. Ensure that the bottom
of the template touches the floor
or the top of the skirting board,
in order that the fitting height
can be adjusted.
,
-
WALL
MOUNTING PROCEDURE
Power outputs
Width fixing holes
(W)
1000
1500
2000
Installation of the wall-mounting brackets
Stage 2
Find the power of your radia-
tor and drill the corresponding
holes into the wall.
- The three wires must be connected in an electrical
connection fuse spur box which complies with ap-
plicable standards.
- In accordance with european standards, the use of a
plug to connect the equipment to a power socket
is forbidden.
ELECTRICAL CONNECTIONS
Monophase power supply 230V +/-10% 50Hz
You must keep the pilot wire insulated if it is
not used.
- Blue wire: Neutral
- Brown wire: Phase
- Black wire: Pilot wire
X =
(mm)
299
541
784
Remove the template then screw
the wall-mounting brackets of
the electric radiator into the wall.
IMPORTANT: use a screw
anchor which is suitable in re-
lation to the wall type (screws
and screw anchors not sup-
plied: screw Ø 6mm max).
5
X
H
357mm
244mm
244mm
Floor
Stage 3