Important:
If the pilot fl ame goes out for any reason, wait for 5 minutes
before attempting to re-light it.
If the pilot light does not ignite after 3 ignition attempts;
close the gas tap and warn the fi tter.
Once the pilot light is burning, the main burner must ignite
within 10 seconds automatically.
If this does not happen, immediately close the gas tap and
warn the fi tter.
If the main burner ignites with a pop; immediately close the
gas tap and warn the fi tter.
Pilot gas adjustment screw
(Factory set) (Puncture the casing
with a small screwdriver)
Figure 4: Gas regulating block
• Possible error messages:
* 3 seconds: short beeps, audible when the motor-knob operates:
Receiver batteries need changing soon (having heard this signal, the
appliance can be ignited another ten times approximately).
* 5 seconds: unbroken beeps:
Error. For example, one of the cables may not be properly connected.
Important:
If the pilot fl ame goes out, then wait for
at least 5 minutes before repeating the
above procedure.
18
8-wire Receiver Jack
Adjustment screw
Maximum burner pressure
(Factory set and sealed)
Microswitch
Instructions for use
English
Motor-knob