Upgrade a two-cabinet system with metal cable to Option 11C
9
Connect the fiber-optic cable to the connector on the Fiber
Expansion Daughterboard as shown in Figure 28 on page 74
Use of the fiber-optic interface product in the Option 11C is
considered safe. However, as a precaution, do not look directly at the
optical port or the end of fiber-optic cable. The cable or port can cause
eye exposure beyond the limits of Maximum Permissible Exposure
recommended in some areas. For example, this condition can occur
during cable testing or under light magnification. Do not remove
protective caps or plugs until you are ready to connect the cable.
Use one of the following methods:
— If using the A0632902 (was A0618443) cable:
a Remove the two protective plugs from the Fiber Expansion
Daughterboard.
b Connect the cable to the Fiber Expansion Daughterboard.
Make sure the V-shaped groove on the cable connector faces
outward and the connector seats tightly. The marking (if there
is one) on the connector is not visible when you make the
correct connection. See Figure 29 on page 75.
— If using glass fiber-optic cable:
a Remove the protective plug from the Fiber Expansion
Daughterboard. Remove the protective cap from the
corresponding plug (Tx or Rx) on the glass fiber-optic cable.
b Insert the plug in its identified connector on the daughterboard.
c Lock the connector in position by turning it a half turn
clockwise. See Figure 30 on page 76.
d Repeat these steps for the second fiber-optic connection.
— If using a glass fiber extension:
Connect the extension from the daughterboard to the main
fiber-optic cable. Make sure you do not interchange the transmit
and receive leads.
WARNING
Option 11C and 11C Mini
Page 73 of 224
Upgrade Procedures Guide
.