Assign TDS/DTR, XTD, and SDI functions
Procedure 14
Move SDI ports while keeping TDS/DTR
1
Disable SDI ports 1 and 2 in LD 37.
Use the DIS TTY N command, where N is the SDI port number.
2
Remove the SDI ports using LD 17.
To remove TTY ports 1 and 2, follow the instructions in Table 18 for
each port:
Table 18
LD 17 - Remove SDI ports 1 and 2.
Prompt
Response
REQ
CHG
TYPE
ADAN
ADAN
OUT TTY X
3
Configure SDI ports on the SSC card using LD 17 (see Table 19).
Table 19
LD 17 - Configure SDI ports on SSC card.
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
NEW TTY X
CDNO
0
PORT
X
DES
aaa...a
BPS
150, 300, 600, 1200,
2400, (4800), 9600,
19200
BITL
5, 6, 7, (8)
STOP
(1), 1.5, 2
PARY
ODD, EVEN, (NONE)