Page 176 of 224
553-3021-250
Standard 7.00
Upgrade Option 11C/11C Mini software to a new release
6
Log in to the system.
a
Type LOGI and press <CR>.
3$66"
Respond to prompt.
b
Note: The response to
response is an example only.
PASS?
0000 <CR>
LD 143 <CR>
UPGRADE <CR>
c
Look for the following message:
62)7:$5( ,167$//$7,21 352*5$0
• If the message displays, go to Step 7 on page 176.
• If the message does not display, repeat Step 6 on page 176
(this step) and make sure you enter the correct information.
7
Call up the Software Installation Program during a SYSLOAD.
Note: Perform this step when starting the Software Installation
Program during a SYSLOAD. To start the program using Overlay 143,
ignore this step and do Step 6 on page 176 instead.
Start a system reload (SYSLOAD) by setting the circuit breaker on the
front of the power supply to OFF then to ON.
Note: A SYSLOAD can take from 20 to 30 minutes.
During SYSLOAD, the following prompt appears:
FIVE SECONDS TO ENTER CONTROL-I TO INVOKE SOFTWARE
INSTALLATION PROGRAM
3UHVV DQG KROG ¨FRQWURO© NH\ DQG SUHVV ¨,©
April 2000
displays.
3$66"
is distinct in each system. The following

Advertisement