Operation; Technical Specifications - Vector TCI-W Manual

Universal controller
Hide thumbs Also See for TCI-W:
Table of Contents

Advertisement

Technical specifications

Warning! This device is intended to be used for comfort applications. Where a device failure endangers human life and/or
property, it is the responsibility of the owner, designer and installer to add additional safety devices to prevent or detect a
system failure caused by such a device failure. The manufacturer of this device cannot be held liable for any damage
caused by such a failure.
Failure to follow specifications and local regulations may endanger life, cause equipment damage and void warranty.
Power Supply
Power Requirements
Power Consumption
Electrical Connection
Clock backup
Signal inputs
Universal Input
Input Signal
Resolution
Impedance
Universal Input
Range
Accuracy
Humidity Sensor AES1-HT-Ax:
Range
Measuring Accuracy
Hysteresis
Repeatability
Stability
Signal outputs
Analog Output
Output Signal
Resolution
Maximum Load
Relays Outputs
Type of disconnection
AC Voltage
DC Voltage
Insulation strength
between relays contacts and system
electronics:
between neighboring contacts:
Environment

Operation

Climatic Conditions
Temperature
Humidity
Transport & Storage
Climatic Conditions
Temperature
Humidity
Mechanical Conditions
Standards
Product standards
Automatic electrical controls for household
and similar use
Special requirement on temperature
dependent controls
Degree of Protection
Pollution Class
Safety Class
Overvoltage Category
General
Material:
Dimension (H x W x D)
Weight (including package)
Doc: 70-00-0158, V1.1, Date: 20160621
Subject to alteration
conforms to
EMC Standard 89/336/EEC
EMEI Standard 73/23/EEC
Cover, back part
Mounting Plate
© Vector Controls GmbH, Switzerland
TCI-W Universal Controller
24 VAC ±10%, 50/60 Hz,Class 2, 2.0 A, 48 VA max.
24 VDC ±10%
Max. 3 VA
Terminal Connectors
2
0.34...2.5 mm
wire (AWG 24...12)
Min. 48 hours
Setting for Voltage or Current
0–10 V or 0–20 mA
9.76 mV or 0.019 mA (10 bit)
Voltage: 98kΩ
Current: 240Ω
Input configured to remote temperature (RT) or digital input (DI)
NTC (Sxx-Tn10 sensor): -40...140 °C (-40...284 °F)
-40...0 °C (-40...32 °F): 0.5 K
0...50 °C (32...122 °F): 0.2 K
50...100 °C (122...212 °F): 0.5 K
> 100 °C (> 212 °F): 1 K
Capacity sensor
0...100 % rH
See Figure to the right
 1%
 0.1%
< 0.5% / year
DC 0–10 V / 0–20 mA
9.76 mV / 0.019 mA
Voltage: ≥1kΩ
Current: ≤250Ω
Micro-interruption
0...48 VAC, 2(1.2)A max. (Observe local regulation)
0...30 VDC, 2A max.
2000V AC to EN 60 730-1
1250V AC to EN 60 730-1
To IEC 721-3-3
class 3 K5
0...50 °C (32...122 °F)
<95 % r.H. non-condensing
To IEC 721-3-2 and IEC 721-3-1
class 3 K3 and class 1 K3
-25...70 °C (-13...158 °F)
<95 % r.H. non-condensing
class 2M2
EN 61 000-6-1/ EN 61 000-6-3
EN 60 730 –1
EN 60 730 – 2 – 9
IP30 to EN 60 529
II (EN 60 730-1)
III (IEC 60536)
I (EN 60 730-1)
Fire proof ABS plastic (UL94 class V-0)
Galvanized Steel
Front part: 21 x 88 x 88mm (0.8 x 3.5 x 3.5 in.)
Power case: ø 58 x 32 mm (ø 2.3" x 1.3")
TCI-W11 = 250g (8.8 oz), TCI-W22 = 265g (9.3 oz)
O
PERATION
Max rH tolerance at 25°C (77°F)
%rH
±5
±4
AES1-HT-A5
±3
AES1-HT-A3
±2
AES1-HT-A2
±1
±0
0
10 20 30 40
50 60 70 80
90
10
0