Dimensions, mm(inch)

88 (3.5)
Connection
0-48VAC, 0-30VDC
24V AC/DC
2
G
1
G0
0V (COM)
0V AC
0-48VAC, 0-30VDC
24V AC/DC
2
G
1
G0
0V (COM)
0V AC
Terminal Description
G0
Power supply:
G
Power supply:
Q..
Binary outputs:
X
Universal input:
U1, u2
Ym1
Analog output:
X
Internal temperature input
T1
X
Internal humidity input if AES1-HT is inserted
H1
Use copper, twisted pair, conductors only. The operating voltage must comply with the requirements for safety extra-low
voltage (SELV) as per EN 60 730. Use safety insulating transformers class II with double insulation as per EN 60 742;
they must be designed for 100% ON-time. When using several transformers in one system, the connection terminal 1
must be galvanic connected. TCI is designed for operation of AC 24 V safety extra-low voltage and is short-circuit-proof.
Supplying voltages above AC 24 V to low voltage connections may damage the controller or other devices. Connection to
voltages exceeding 42 V endangers personnel safety.
Doc: 70-00-0158, V1.1, Date: 20160621
Subject to alteration
32 (1.2)
X
U1
3
1
7
Q13
G0
X1
4
5
Q14
Q24
Y
Y
B1
B2
X
U1
3
1
7
Q13
G0X1
4
5
Q14
Q24
Y
Y
B2
B1
0V, -24VDC; common for power supply, analog in- and outputs
24VAC, +24VDC
Potential free relays contacts (see technical specification)
Yb1,b2
Binary output common
NTC 10kΩ @ 25°C (77°F), 0...10 V or 0...20 mA(selectable by jumper)
0...10 V or 0...20 mA
© Vector Controls GmbH, Switzerland
TCI-W Universal Controller

Installation

21
(0.8)
 Install the controller on an easy accessible
interior wall, approx. 1.5 m above the floor
in an area of average temperature.
 Avoid direct sunlight or other heat sources,
e.g. the area above radiators and heat
emitting equipment.
 Avoid locations behind doors, outside walls
and below or above air discharge grills and
diffusers.
 Location of mounting is less critical if
external temperature sensors are used.
 Ensure adequate air circulation to dissipate
heat generated during operation.
 Observe local regulations.
Do not mount in a wet or condensation
prone environments.
X
U2
1
8
X
G0X2
T1
16
G0Y1
Y
M1
X
T1
1
6
G0
Y1
Y
M1
*
O
PERATION
Warning:
Live Electrical
Components!
X
During installation,
H1
testing, servicing and
troubleshooting of
TCI-W22
Vector Controls
products, it may be
necessary to work with
live electrical
components. Have a
qualified licensed
electrician or other
individual who has been
properly trained in
handling live electrical
components perform
these tasks. Failure to
follow all electrical
safety precautions
X
when exposed to live
H1
electrical components
TCI-W11
could result in death or
serious injury.