Operation
7.
Place the master TW into master mode by either setting the mode up in the
menu system or through the SCPI system.
SCPI:
• If there are two slaves, GPIB Send to the master: SYST:CHASSIS 3
The chassis number counts the master chassis as one of the chassis. If there is
one slave, the message will be SYST:CHASSIS 2
Front Panel Menu:
• Press Up Arrow to get into the menu system.
• Press the Up Arrow enough times to get to CONFIG and press the ENT key.
• Press the Up Arrow enough times to get to CHASSIS and press the ENT key.
• Press the Left or Right Arrow keys to increment or decrement the chassis
number, then press the ENT key. For two slaves, set chassis number to 3.
• Press the ABC/Back key until the TW reads "SYS RESTART" and the TW will
automatically reboot.
8.
Now turn off the master TW while it reads "Sys Restart" or while it is searching
for slaves.
9.
Turn on the next (slave) TW.
10.
Place the first slave TW into slave mode by either setting the chain address in
the menu system or through the SCPI system.
SCPI:
• GPIB Send to the slave: SYST:CHAIN 1
The chain address number specifies the address of this slave TW.
Front Panel Menu:
• Press Up Arrow to get into the menu system.
• Press the Up Arrow enough times to get to CONFIG and press the ENT key.
• Press the Up Arrow enough times to get to CHAIN and press the ENT key.
• Press the Left or Right Arrow keys to increment or decrement the slave
address (chain address), then press the ENT key.
• Press the ABC/Back key until the TW reads "SYS RESTART" and
automatically reboots.