Operation
INSTALLED
Specify the quantity of installed amplifiers here
INST QTY
Sets the quantity of installed amplifiers.
STORAGE
The setpoints that are specified via the front panel or the command interface
(GPIB/serial) are saved and retrieved to EEROM non-volatile memory using the
following menu commands:
STORE
You can save the present TW setup to locations 0-98. The following program
data are saved and restored:
A,B,C volt setpoints
A,B,C current limit setpoints
A,B,C offset volt setpoints
Voltage Range (High, Low)
B phase angle, C phase angle setpoints
Frequency setpoint
Current type (Shut, Fold)
Current limit timeout
Coupling type (AC, DC, ACDC)
Parallel mode (On, Off) of internal amplifiers
Clock/Lock Sync mode (SyncOut, RefOut, RefIn, TrigIn)
Aux Input mode (Off, Direct, Gain)
Sense mode (Local, Remote)
Chassis Quantity
IEC Output impedance (On, Off)
NOTE: Parameters previously saved to location 0 are automatically
read in at power-up time.