S E CT I ON 3
The TrueWave is programmable via the front panel and through the GPIB/ RS-232
command interface system. The unit is factory configured to power up in standby mode
(output relay open) and it will operate in this manner unless it is programmed otherwise.
3 .1
P R OGR AM PAR AME T E R S
The following parameters are set by quick key combinations on the front panel:
• Voltage setpoint of phases ABC, phase A alone, phase B, or phase C
• Current Limit of phases ABC, phase A alone, phase B, or phase C
• Phase angle of A-B
• Phase angle of A-C
• Frequency setpoint of TW (all phases)
• Present voltage range (0..156V, 0..312V)
• Output relay state (the output relay must be closed to source current)
3 .2
ME NU PAR AME T E R S
The following parameters are programmed by means of the optionally password
protected front panel menu system:
• GPIB address
• Over-current Foldback/Shutdown/Timeout modes
• Coupling to AC,DC or AC-DC
• Parallel mode On/Off
• EXT connector to Direct, Gain, or no control of the power amplifiers
• SYNC connector to Sync Out, Phase A Out, or Phase A ln, or Trig In
• Voltage sense point to Local or Remote
• Chassis quantity (master-slave mode)
• IEC output impedance On/Off
• Store or Recall system state to/from 99 non-volatile memory locations
• Specify at power-up that the output relay will automatically close or not.
• Set or clear menu protection password.
Elgar TrueWave
OP E R AT I ON
3-1